SERCOS III by Motor Type

Industrial Ethernet is the name given to the use of the Ethernet network protocol in an industrial environment, for automation and process control.

A number of techniques are used to adapt the Ethernet protocol for the needs of industrial processes, which must provide real time behavior.

By using non-proprietary protocols, automation systems from different manufacturers can be interconnected throughout a process plant.

Industrial Ethernet takes advantage of the relatively larger marketplace for computer interconnections to reduce cost and improve performance of communications between industrial controllers.

Industrial Ethernet (IE) components used in plant process areas must be designed to work in harsh environments of temperature extremes, humidity, and vibration that exceed the ranges for IT equipment intended for installation in controlled environments.

Read more in these articles.

SpecificationMAC + moduleMAC servo with MAC00-Ex4 expansion moduleMAC00-ES4MAC Gen IIIBuilt-in interfaceMAC404M2-GAAQES2MIS with SMC66ServoStep integrated stepperMIS171S16ESH266MIS with SMC67ServoStep integrated stepperReference part number pending
AvailableYesYesYes-
Application ProtocolSERCOSIII ver. 1.1.2SERCOSIII ver. 1.1.2SERCOSIII ver. 1.1.2-
CompanyBosch RexrothBosch RexrothBosch Rexroth-
MacTalk over RS232YesYesYes-
IIoT, IoT, Industrie 4.0YesYesYes-
MacTalk over EthernetYes*5)Yes*5)Yes*4)-
ScopeYesYesPlanned-
ePLC transferYes*5)Yes*5)Yes*4)-
Load DefaultYes*5)Yes*5)Yes*4)-
Firmware UpdateYes*5)Yes*5)Yes*4)-
Transport Protocol--0-
SyncronizationYesYesYes-
Drive profileYesYesYes-
Sync. Cycletimes1 or 2 ms1 or 2 ms1, 2, 3, 4, 6 or 8 ms-
Sync. jitter±1 μs±1 μs±1 µs-
Network Minimum cycle time250 µs250 µs250 µs-
Module Minimum cycle time: MAC400-4500500 us500 us--
Address Range511511511-
Max. BaudrateEthernet 100 Mbit/sEthernet 100 Mbit/sEthernet 100 Mbit/s-
Forwarding delay<1 µs<1 µs<1 µs-
NetworkLine, RingLine, RingLine, Ring-
StandardsIEC 61491 merged into IEC 61158IEC 61491 merged into IEC 61158IEC 61491 merged into IEC 61158-
Further supported protocols----
User org.SercosSercosSercos-
User org. Linkwww.sercos.orgwww.sercos.orgwww.sercos.org-
MAC + module · MAC Gen III

*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) NOT applicable for MAC050-MAC141. *3) IIoT: Industrial Internet of things, IoT: Internet of things. *4) Requirements: EtherCAT Master. *5) Connect to Sercos master when using ring topology otherwise connect to last motor in line.

MIS with SMC66