SERCOS III by Motor Type
Industrial Ethernet is the name given to the use of the Ethernet network protocol in an industrial environment, for automation and process control.
A number of techniques are used to adapt the Ethernet protocol for the needs of industrial processes, which must provide real time behavior.
By using non-proprietary protocols, automation systems from different manufacturers can be interconnected throughout a process plant.
Industrial Ethernet takes advantage of the relatively larger marketplace for computer interconnections to reduce cost and improve performance of communications between industrial controllers.
Industrial Ethernet (IE) components used in plant process areas must be designed to work in harsh environments of temperature extremes, humidity, and vibration that exceed the ranges for IT equipment intended for installation in controlled environments.
| Specification | MAC + moduleMAC servo with MAC00-Ex4 expansion moduleMAC00-ES4 | MAC Gen IIIBuilt-in interfaceMAC404M2-GAAQES2 | MIS with SMC66ServoStep integrated stepperMIS171S16ESH266 | MIS with SMC67ServoStep integrated stepperReference part number pending |
|---|---|---|---|---|
| Available | Yes | Yes | Yes | - |
| Application Protocol | SERCOSIII ver. 1.1.2 | SERCOSIII ver. 1.1.2 | SERCOSIII ver. 1.1.2 | - |
| Company | Bosch Rexroth | Bosch Rexroth | Bosch Rexroth | - |
| MacTalk over RS232 | Yes | Yes | Yes | - |
| IIoT, IoT, Industrie 4.0 | Yes | Yes | Yes | - |
| MacTalk over Ethernet | Yes*5) | Yes*5) | Yes*4) | - |
| Scope | Yes | Yes | Planned | - |
| ePLC transfer | Yes*5) | Yes*5) | Yes*4) | - |
| Load Default | Yes*5) | Yes*5) | Yes*4) | - |
| Firmware Update | Yes*5) | Yes*5) | Yes*4) | - |
| Transport Protocol | - | - | 0 | - |
| Syncronization | Yes | Yes | Yes | - |
| Drive profile | Yes | Yes | Yes | - |
| Sync. Cycletimes | 1 or 2 ms | 1 or 2 ms | 1, 2, 3, 4, 6 or 8 ms | - |
| Sync. jitter | ±1 μs | ±1 μs | ±1 µs | - |
| Network Minimum cycle time | 250 µs | 250 µs | 250 µs | - |
| Module Minimum cycle time: MAC400-4500 | 500 us | 500 us | - | - |
| Address Range | 511 | 511 | 511 | - |
| Max. Baudrate | Ethernet 100 Mbit/s | Ethernet 100 Mbit/s | Ethernet 100 Mbit/s | - |
| Forwarding delay | <1 µs | <1 µs | <1 µs | - |
| Network | Line, Ring | Line, Ring | Line, Ring | - |
| Standards | IEC 61491 merged into IEC 61158 | IEC 61491 merged into IEC 61158 | IEC 61491 merged into IEC 61158 | - |
| Further supported protocols | - | - | - | - |
| User org. | Sercos | Sercos | Sercos | - |
| User org. Link | www.sercos.org | www.sercos.org | www.sercos.org | - |
*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) NOT applicable for MAC050-MAC141. *3) IIoT: Industrial Internet of things, IoT: Internet of things. *4) Requirements: EtherCAT Master. *5) Connect to Sercos master when using ring topology otherwise connect to last motor in line.
*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) IIoT: Industrial Internet of things, IoT: Internet of things. *3) Requirements: EtherCAT Master. *4) Connect to Sercos master when using ring topology otherwise connect to last motor in line.