DEMO_MIS232_Actuator

Demo_MIS232_Actuator, easy plug and play solution.

Plug the power cord into a 230 VAC type K socket (Danish wall socket) and the Demo is good to go.

Contact Us

Program overview:

  1. Energy consumption - Motor 1 closed-loop, Motor 2 open-loop. Watch displays, Motor 1 will use less power.
  2. Abs. encoder - Motor 1 open-loop with abs. encoder, Motor 2 open-loop without encoder. Motor 1 will continue after stall, Motor 2 must perform new zero search (use <<start>> button after stall)
  3. Analogue to position - Motor 1 closed-loop max. speed 2000 RPM without stall, Motor 2 open-loop, stall at 2000 RPM.
  4. Analogue torque control - Motor 1 closed-loop, will know if its moving, Motor 2 open-loop will not know it has stopped.
  5. Analogue to velocity - Speed adjust using AN-IN up to 3000 RPM, Motor 1 closed-loop will not stall, Motor 2 open-loop will stall.
  6. Power off. Abs. encoder - Motor 1 abs. encoder, Motor 2 without. Actuators will move back and forth, after Power off and on motor 1 will continue, motor 2 will perform new homing.

PDF download.

Motor Program download.

Motors and accessories used in this Demo: MIS231S, PSU48-240

Flight case measurements

Weight of case without content

DEMO_MIS232_Actuator measurements

More JVL Demos can be found here.