Home / Protocols / EtherNet/IP

EtherNet/IP · Rockwell Automation Technology Partner

EtherNet/IP for JVL Servo & Stepper Motors

All JVL motor families are available with EtherNet/IP, with Add-On Instructions for Studio 5000.

Find your filesMIS: no EDS file needed
EtherNet/IP
Rockwell Automation
Technology Partner
3Motor families
AOIsfor Studio 5000
ODVAConformance tested
DLRDaisy chain + ring

Overview

Motors and files at a glance

Check the part number on the motor label.

MotorRecognise it byAdd in Studio 5000 asEDS fileAOI packageProgram example
Classic MAC
servo motor with module
Module MAC00-EI4 / EI41 on the motorDevice from EDSJVL_MAC_ServoMotors.edsMAC_AOI.zipExample 0001
MAC Gen III servo
built-in EtherNet/IP
EI in part no., e.g. MAC404M2-GAAQEI2Device from EDS
Studio 5000 V37+
MACG3_8Regs_Cyclic.edsMAC_G3_V1.0.zipIn the AOI package
MIS / MIL stepper
closed-loop ServoStep
EI in part no., e.g. MIS171S16EIH266Generic Ethernet Module
Studio 5000 V24+
Not neededMIS_AOI.zipWireless example

Before you start

How JVL motors work on EtherNet/IP

Motor + drive + controller

All built into the motor. Connect power and Ethernet directly and daisy-chain motor to motor.

I/O device

The motor runs its own motion profile. The PLC exchanges 8 read and 8 write words (32-bit) every cycle.

MacTalk

Needed for tuning, scope, ePLC programming and firmware. Tasks that need MacTalk

Add-On Instructions

A communication AOI runs every scan. Motion AOIs: move, jog, home, stop, disable, fault reset. Position in counts, mm/inch or degrees.

Quick start

First motor running

  1. Set IP address and cyclic dataOnce per motor, from Studio 5000 or MacTalk. MAC Gen III: the default cyclic setup is correct; only the IP address must be set.
  2. Add the motor in Studio 5000Classic MAC: install the EDS file, then New Module → JVL motor. MIS/MIL: Generic Ethernet Module, settings here.
  3. Import the AOIs and data typesFrom the AOI package for your motor.
  4. Call the communication AOI every scanMIS_COM or MAC_G3_COM, with two MSG instructions (read/write) for homing and other acyclic parameters.
  5. MoveE.g. MIS_Position or MAC_G3_MAM, absolute or relative.

Tasks that need MacTalk

Certain setup situations require JVL's MacTalk software.

TaskStudio 5000MacTalk
Set IP address✓✓
Set cyclic data words✓✓
Program and run the motor from the PLC✓ AOIs
Tuning✓
Diagnostics and scope✓
Programming the embedded ePLC✓
Firmware update and backup of the motor setup✓

Setup from Studio 5000

The motor starts on its factory IP address. With the PLC on the same subnet, MSG instructions (CIP Generic) set it up:

  • IP, subnet, gateway: TCP/IP object class 0xF5, attribute 5.
  • Cyclic words: module registers 16-31 (class 0x65); bit 6 in register 6 = 8 words.
  • Save: 16 to module register 15, then power-cycle.
  • DHCP: bit 10 in module register 6.

LB0056 section 4.2 · Chapter 10

Setup with MacTalk

Connect over Ethernet or the serial cable. Set IP address and cyclic data in the EtherNet/IP tab and press Apply and save. The quickest way to get the first motor on the network.

Benefits of MacTalk

  • Fast prototyping: run and tune the motor before the PLC program exists.
  • Diagnostics: live status, errors and registers.
  • Scope: record position, velocity and torque.
  • ePLC: program the motor's embedded PLC for fast-response tasks triggered by I/O, without a round trip to the main PLC.
  • Backup: save the full motor setup to a file.

Downloads

Files by motor type

EDS

EDS file - Classic MAC motors with module

JVL_MAC_ServoMotors.EDS.zip

Install with the EDS Hardware Installation Tool. The MAC then appears as a JVL device under New Module.

You need it: once per Studio 5000 installation.
AOI

Add-On Instructions + AOI manual

MAC_AOI.zip · 2023-04-21

Add-On Instructions for Classic MAC motors with an EtherNet/IP module.

You need it: to control the motor from ladder logic without writing your own register handling.
EXAMPLE

Example 0001 - cyclic I/O and explicit messages

jvl_example_0001.zip + PDF

Position mode on a MAC400 with a 3-rung ladder program, without AOIs. For programmers who want to work directly with the motor registers.

MANUAL

EtherNet/IP reference

Ethernet User Manual LB0056 · chapter 4

LEDs, cyclic I/O, explicit messaging, configuration from the PLC and register access.

You need it: when you go beyond the AOIs.
CERT

ODVA conformance certificate

11205_tou_040914.pdf

For customer or machine documentation.

MIS EDS file

MIS / MIL motors need no EDS file

MIS and MIL motors with EtherNet/IP have no EDS file. They are added as a Generic Ethernet Module with the settings below. The 8 read and 8 write words are set in the motor once, from Studio 5000 or MacTalk.

Module typeETHERNET-MODULE Generic Ethernet Module
Comm FormatData - DINT
IP Addressthe motor's IP address
Input assemblyInstance 101, size 8 (32-bit)
Output assemblyInstance 100, size 8 (32-bit)
ConfigurationInstance 1, size 0 (8-bit)

Questions programmers usually ask

Do I need MacTalk?

For tuning, diagnostics, scope, ePLC programming, firmware updates and backup of the motor setup. IP address and cyclic data can also be set from Studio 5000. Tasks that need MacTalk

What units does the position use?

Set ApplicationType in the communication AOI: 0 = counts and rpm, 1 = linear units (e.g. mm and mm/s, with travel per revolution and gear ratio), 2 = degrees.

Which homing methods are available?

MIS: set home position, home to sensor, home to end stop (torque). Homing speed, torque limit and offset are sent by message, which the example rungs show.

How do I read a value that is not in my cyclic data?

Use a MSG instruction. The instance is the register number. Motor registers 1-255 are in object class 0x64, 256-511 in class 0x66, module registers in class 0x65.

What happens if the network connection is lost?

Set in the motor's EtherNet/IP error handling: the motor goes to passive mode or to velocity 0.

How fast is the cyclic update?

Network minimum cycle time is 2 ms. The motor's own minimum depends on the model; see the specifications below.

Can I daisy-chain motors and use a ring?

Yes. The built-in Ethernet switch lets you go motor to motor with one cable, and Device Level Ring (DLR) is supported.

Who do I call if I get stuck?

Your local JVL distributor, or JVL support: support@jvl.dk. Have the motor part number and serial number (on the label) ready.

EtherNet/IP specifications

Application protocolCIP
TransportTCP/IP, UDP/IP
StandardsIEC 61158, IEC 61784, ODVA EtherNet/IP
Further protocolsDHCP, ACD, DLR
Baud rate100 Mbit/s
Cyclic dataUp to 8 read + 8 write words (32-bit)
Network minimum cycle time2 ms
Module minimum cycle timeMAC050-141: 4 ms (1/1 words), 20 ms (5/5), 32 ms (8/8) · MAC400-3000: 1 ms

EtherNet/IP by Motor Type

How EtherNet/IP is implemented across the JVL motor families

SpecificationMAC + moduleMAC servo with MAC00-Ex4 expansion moduleMAC00-EI4MAC Gen IIIBuilt-in interfaceMAC404M2-GAAQEI2MIS with SMC66ServoStep integrated stepperMIS171S16EIH266MIS with SMC67ServoStep integrated stepperReference part number pending
AvailableYesYesYes-
Application ProtocolCIPCIPCIP-
CompanyRockwell AutomationRockwell AutomationRockwell Automation-
MacTalk over RS232YesYesYes-
IIoT, IoT, Industrie 4.0YesYesYes-
MacTalk over EthernetYesYesYes-
ScopeYesYesPlanned-
ePLC transferYesYesYes-
Load DefaultYesYesYes-
Firmware UpdateYesYesYes-
Transport ProtocolTCP/IP, UDP/IPTCP/IP, UDP/IPTCP/IP, UDP/IP-
SyncronizationPlannedPlannedPlanned-
Drive profilePlannedPlannedPlanned-
Sync. Cycletimes----
Sync. jitter----
Network Minimum cycle time2 ms2 ms2 ms-
Module Minimum cycle time: MAC050-3204 ms at 1/1 20 ms at 5/5 32 ms at 8/8 *1)4 ms at 1/1 20 ms at 5/5 32 ms at 8/8 *1)--
Module Minimum cycle time: MAC400-45001 ms1 ms--
Address Range655356553565535-
Max. BaudrateEthernet 100 Mbit/sEthernet 100 Mbit/sEthernet 100 Mbit/s-
Forwarding delay10-130 µs10-130 µs10-130 µs-
NetworkSwitches, routers, wirelessSwitches, routers, wirelessSwitches, routers, wireless-
StandardsIEC 61158, IEC 61784, ODVA Ethernet/IP standardIEC 61158, IEC 61784, ODVA Ethernet/IP standardIEC 61158, IEC 61784, ODVA Ethernet/IP standard-
Further supported protocolsDHCP, ACD, DLRDHCP, ACD, DLRDHCP, ACD, DLR-
User org.ODVAODVAODVA-
User org. Linkwww.odva.orgwww.odva.orgwww.odva.org-
MAC + module · MAC Gen III

*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) NOT applicable for MAC050-MAC141. *3) IIoT: Industrial Internet of things, IoT: Internet of things. *4) Requirements: EtherCAT Master. *5) Connect to Sercos master when using ring topology otherwise connect to last motor in line.

MIS with SMC66

*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) IIoT: Industrial Internet of things, IoT: Internet of things. *3) Requirements: EtherCAT Master. *4) Connect to Sercos master when using ring topology otherwise connect to last motor in line.

EtherNet/IP servo and stepper motors from JVL

JVL integrated servo motors (MAC) and integrated stepper motors (MIS/MIL ServoStep) are available with EtherNet/IP for Allen-Bradley ControlLogix and CompactLogix controllers. Each motor combines motor, encoder, drive and controller in one housing and connects directly to the EtherNet/IP network, with a built-in Ethernet switch for daisy-chaining and support for Device Level Ring (DLR). As a Rockwell Automation Technology Partner, JVL provides Add-On Instructions (AOI) and example projects for Studio 5000 / RSLogix 5000, EDS files for MAC servo motors, and setup guidance for MIS stepper motors as a Generic Ethernet Module, where no EDS file is required.

EtherNet/IP is the ODVA industrial Ethernet protocol based on CIP (Common Industrial Protocol), using TCP/IP and UDP/IP over standard 100 Mbit/s Ethernet. JVL EtherNet/IP motors are ODVA conformance tested and support DHCP, ACD and DLR, so they fit directly into Rockwell Automation and other EtherNet/IP networks.

Help with your first motor

Your local JVL distributor or JVL support will help you get started.

Find a Distributor

Contact Support