The JVL IO-Link is now built into the IO connectors of a JVL motor.
IO-Link is becoming increasingly popular as low cost alternative to Ethernet and other serial protocols. JVL motors can now also connect to IO-Link with a build in IO-Link for fast and easy interface. It does not use external gateway or CPU but communicate directly with JVL main microprocessor for fast response time. Normally would you think IO-Link with a 230 kbit serial communication is a slow compared to Ethernet but with JVL FastMAC 2 byte protocol can response time <1mS be achieved. IO-link will be supported on all new JVL motors like MAC motor® integrated servo MACxx04/02 series and ServoStep™ integrated MISxx stepper motors.
JVL’s IO-Link features:
- AOI and function block available for Rockwell and Siemens PLC
- IODD files for plug and play simplified Integration to PLC, supporting the different JVL modes of operation
- Data storage for easy commissioning and replacement Event handling for timestamped diagnostics
- Any IO-Link master will be able to control the motor
- All motion functions can be controlled through the IO-Link channel
- All motor registers can be read or write
- ModeFM ultra compact processdata format with 2 byte for extremely low IO-Link cycletime <1mS
- One cable with both Power and IO-Link for low power applications
- Minimize stock Available with both IO-Link and Ethernet based communication
- Easy commissioning using IODD files and Parametrization directly from the IO-Link master
- Mode66 for 6 in and 6 out registers similar to the well known JVL Ethernet concept
- Mode88 for 8 in and 8 out 100% user configurable register setup, similar to the well known JVL Ethernet concept
- Conformance tool tested and passed
- IO-Link standard 1.1.4 supported
- Specialized Gripper mode Simple control with high servo-controlled accuracy




Typical applications:
- Format adjustment. Replacement of handwheel adjustment
- Gripper with high precision and dynamics using the JVL ServoStepper control system
- Pick and place operations. Move between 2-8 pre-selected positions with pre-configured velocity, acceleration and torque setting
- Air-cylinder replacement with precise acceleration and speed control
- Setup axis, only requiring a minimal bandwidth and no hard timing or synchronization requirement
Topology Rockwell example, one IO-Link for each motor

| Milestones for IO-Link Functionality | |
| Data storage | Q1 - 2025 |
| Event Handling | Q1 - 2025 |
| Diagnostic | Q1 - 2025 |
| Block parameter | Q1 - 2025 |
Response time (Preliminary data)
| PLC and IO-Link Master | ModeFM (FastMAC) | Mode 66 | Mode 88 |
| Rockwell CompactLogix 5380 PLC (Rockwell, EthernetIP) | |||
| Baumer CM50.EIP, 1 ms RPI | 10 ms | 25 ms | |
| Rockwell Armorblock 1732E-8IOLM12R, 2 ms RPI | 30 ms | 30 ms | |
| Siemens 1511-1 PN PLC (Siemens, Profinet) | |||
| Balluff BNI PNT-507-005-Z040 | 10 ms | 25 ms | 20 ms |
The measured system cycletime is based on a data value set from the PLC in the motor and read back again. As a reference an EthernetIP equipped MIS motor has a system cycletime of 3 ms, based on 1 ms RPI.
Cyclic timing
JVL IO-Link products
| JVL Part number | Connector | Photo | |
|---|---|---|---|
| IO-Link cable | |||
| WI1000-M12M5TF5T03N | M12 5 pin male / 5 pin female | 3 m | |
| WI1000-M12M5TF5T05N | M12 5 pin male / 5 pin female | 5 m | |
| WI1000-M12M5TF5T20N | M12 5 pin male / 5 pin female | 20 m | |
| JVL IO-Link Master Junction Box | |||
| WI1646-EI8A2D2LK | Ethernet/IP 8AF/2DF/1L | TBD | |
| WI1646-EP8A2D2LK | Profinet 8AF/2DF/1LF/1 | TBD | |
For IO-Link for MAC please check here.