EtherCAT by Motor Type

Industrial Ethernet is the name given to the use of the Ethernet network protocol in an industrial environment, for automation and process control.

A number of techniques are used to adapt the Ethernet protocol for the needs of industrial processes, which must provide real time behavior.

By using non-proprietary protocols, automation systems from different manufacturers can be interconnected throughout a process plant.

Industrial Ethernet takes advantage of the relatively larger marketplace for computer interconnections to reduce cost and improve performance of communications between industrial controllers.

Industrial Ethernet (IE) components used in plant process areas must be designed to work in harsh environments of temperature extremes, humidity, and vibration that exceed the ranges for IT equipment intended for installation in controlled environments.

Read more in these articles.

SpecificationMAC + moduleMAC servo with MAC00-Ex4 expansion moduleMAC00-EC4MAC Gen IIIBuilt-in interfaceMAC404M2-GAAQEC2MIS with SMC66ServoStep integrated stepperMIS171S16ECH266MIS with SMC67ServoStep integrated stepperReference part number pending
Downloads - latest version
Device description fileESI / GSDML / EDS / IODD / XDDZIP2022-08-03ZIPMotor firmware 3.01.042026-11-19ZIP2022-08-03
PLC demo program
AvailableYesYesYes-
Application ProtocolCANopen (DS301 + DSP402)CANopen (DS301 + DSP402)CANopen (DS301 + DSP402)-
CompanyBeckhoffBeckhoffBeckhoff-
MacTalk over RS232YesYesYes-
IIoT, IoT, Industrie 4.0YesYesYes-
MacTalk over EthernetYes 4*)Yes 4*)Yes*3)-
ScopeNoNoPlanned-
ePLC transferYes 4*)Yes 4*)Yes*3)-
Load DefaultYes 4*)Yes 4*)Yes*3)-
Firmware UpdatePlannedPlannedPlanned-
Transport ProtocolEtherCAT, EtherCAT/UDPEtherCAT, EtherCAT/UDPEtherCAT, EtherCAT/UDP-
SyncronizationDC, 32bitDC, 32bitDC, 32bit-
Drive profileCiA402CiA402CiA402-
Sync. Cycletimes1 or 2 ms1 or 2 ms1, 2, 3 or 4 ms-
Sync. jitter±1 μs±1 μs±1 µs-
Network Minimum cycle time<50 µs<50 µs<50 µs-
Module Minimum cycle time: MAC050-3204 ms at 1/1 20 ms at 5/5 32 ms at 8/8 *1)4 ms at 1/1 20 ms at 5/5 32 ms at 8/8 *1)--
Module Minimum cycle time: MAC400-4500360 µs at 1/1 500 µs at 5/5 605 µs at 8/8 *1)360 µs at 1/1 500 µs at 5/5 605 µs at 8/8 *1)--
Address Range655356553565535-
Max. BaudrateEthernet 100 Mbit/sEthernet 100 Mbit/sEthernet 100 Mbit/s-
Forwarding delay<1 µs<1 µs<1 µs-
NetworkLine, Ring, Star, TreeLine, Ring, Star, TreeLine, Ring, Star, Tree-
StandardsIEC 61158, IEC/PAS 62407, IEC 61784-3, ISO 15745-4IEC 61158, IEC/PAS 62407, IEC 61784-3, ISO 15745-4IEC 61158, IEC/PAS 62407, IEC 61784-3, ISO 15745-4-
Further supported protocolsSDO, CoESDO, CoESDO, CoE-
User org.ETGETGETG-
User org. Linkwww.ethercat.orgwww.ethercat.orgwww.ethercat.org-
MAC + module · MAC Gen III

*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) NOT applicable for MAC050-MAC141. *3) IIoT: Industrial Internet of things, IoT: Internet of things. *4) Requirements: EtherCAT Master. *5) Connect to Sercos master when using ring topology otherwise connect to last motor in line.

MIS with SMC66

*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) IIoT: Industrial Internet of things, IoT: Internet of things. *3) Requirements: EtherCAT Master. *4) Connect to Sercos master when using ring topology otherwise connect to last motor in line.