PROFINET · PROFIdrive · PROFIsafe
PROFINET for JVL Servo & Stepper Motors
MAC Gen III runs as a standard PROFIdrive axis in TIA Portal, with PROFIsafe for safety over the same cable. Add the motor, pick the telegram, move it with Siemens' own blocks.
Find your filesChoose control methodPROFIsafe SIL 3 / PL e
Overview
Motors and files at a glance
Check the part number on the motor label.
| Motor | Recognise it by | GSDML file | Control from TIA Portal | PROFIsafe | Program example |
|---|---|---|---|---|---|
| MAC Gen III servo built-in PROFINET | EP in part no., e.g. MAC404M2-GAAQEP2 | GSDML 2026-10-01 | PROFIdrive: technology object or SINA_POSor JVL telegram + JVL library | ✓ | - |
| Classic MAC servo motor with module | Module MAC00-EP4 / EP41 on the motor | GSDML 2024-04-23 | JVL telegram (8 words) + JVL Profinet Library | - | TIA example |
| MIS / MIL stepper closed-loop ServoStep | EP in part no., e.g. MIS171S16EPH266 | GSDML 2024-04-23 | JVL telegram (8 words) + JVL Profinet Library | - | Wireless example |
Before you start
How JVL motors work on PROFINET
Motor + drive + controller
All built into the motor. Connect power and Ethernet directly and daisy-chain motor to motor through the built-in switch.
PROFINET IO device
Name of station and IP address are assigned by TIA Portal (DCP), like any other PROFINET device.
Gen III: a standard drive
PROFIdrive telegrams, so the S7 technology objects and Siemens' drive blocks work without a JVL library.
MacTalk
Gen III: optional, for tuning, scope and diagnostics. Classic MAC and MIS: needed once for the cyclic data setup. Tasks that need MacTalk
MAC Gen III
Choose your control method
Select the telegram when you add the motor in TIA Portal. The default needs no changes.
Drive-based positioning
The motor runs the motion profile. The PLC sends target, speed and ramps with Siemens' SINA_POS block (FB284).
- Telegram 111
- S7-1200 and S7-1500
- Lowest PLC load, simplest program
Technology object
Add the motor as a positioning or synchronous axis and use the PLCopen blocks MC_Power, MC_Home, MC_MoveAbsolute.
- Telegram 3 (speed + encoder)
- Gearing and cam with S7-1500T
- Absolute encoder position in the encoder word, no homing after power-up
JVL registers
8 read and 8 write words, freely mapped to motor registers. Same as Classic MAC and MIS, with the JVL Profinet Library.
- One PLC program for all JVL motors
- Access to any motor register
- Mapping set from TIA Portal
Quick start
First motor running
- Install the GSDML fileOptions → Manage general station description files. The motor appears under Other field devices → PROFINET IO → Drives → JVL.
- Add the motor and keep the default telegramTelegram 111 is preselected. Change it only if you use a technology object (telegram 3).
- Assign the device nameRight-click the motor → Assign device name. The PLC sets the IP address. No MacTalk needed.
- Set the motor parameters in TIA PortalIn the device properties: load factor, filter, direction and limits. The PLC writes them to the motor at every start-up.
- MoveCall
SINA_POS, orMC_MoveAbsoluteon the technology object.
- Set IP address and cyclic dataOnce per motor in MacTalk (Profinet tab): select the 8 read and 8 write registers, then Apply and save. Or from the PLC, see setup without MacTalk.
- Install the GSDML file and add the motorOne device per axis, under Drives → JVL Industri Elektronik A/S → PNS.
- Assign the device nameSame subnet as the PLC.
- Import the JVL Profinet LibraryTIA Portal V14 or higher. Copy the UDTs and the JVL Common + JVL MIS or JVL MAC groups, and create one axis data block per motor.
- Call the Comms block every cycle, then move
JVL_MIS_Comms/JVL_MAC_Comms, then e.g.JVL_MIS_PositionorJVL_MAC_Position.
Tasks that need MacTalk
MacTalk is JVL's PC software for tuning and diagnostics.
| Task | MAC Gen III | Classic MAC, MIS / MIL |
|---|---|---|
| Device name and IP address | TIA Portal | TIA Portal or MacTalk |
| Select telegram / cyclic data | TIA Portal | MacTalk, or from the PLC by acyclic write |
| Load factor, filter, limits | TIA Portal | MacTalk |
| Program and run the motor from the PLC | Siemens blocks or JVL library | JVL library |
| Fine tuning, scope, diagnostics | MacTalk | MacTalk |
| ePLC programming, firmware update, backup | MacTalk | MacTalk |
Cyclic setup from the PLC
Classic MAC and MIS: write the cyclic setup to module registers 16-31, save to flash and restart the module. LB0056 section 6.5.8
Setup with MacTalk
Connect over Ethernet or the serial cable. Set the cyclic data in the Profinet tab and press Apply and save.
Benefits of MacTalk
- Fast prototyping: run and tune the motor before the PLC program exists.
- Scope: record position, velocity and torque.
- ePLC: fast I/O-triggered tasks inside the motor.
- Backup: save the full motor setup to a file.
Service
Swap a motor without a PC
A new motor from stock is named and configured by the PLC. The service technician only changes the motor.
1. Blank name at power-up
Factory default: the motor starts without a name of station, so the PLC can recognise it as new.
2. PLC names it by topology
Wire the ports in the Topology view in TIA Portal. The PLC gives the new motor the name of the port it is plugged into.
3. Parameters from the PLC
MAC Gen III: telegram and motor parameters are stored in the TIA project and written at start-up. The motor runs as the old one did.
MAC Gen III · Functional safety
PROFIsafe: safety over the same cable
MAC Gen III with PROFIsafe takes its safety commands from an F-CPU over PROFINET. No separate safety wiring to each motor, and safety functions beyond STO run in the motor itself.
Stopping functions
- STO Safe Torque Off
- SS1 Safe Stop 1
- SS2 Safe Stop 2
Monitoring functions
- SLS Safely Limited Speed
- SOS Safe Operating Stop
- SSM Safe Speed Monitor
- SDI Safe Direction
- SLP Safely Limited Position
Output functions
- SBC Safe Brake Control
All functions: SIL 3 / PL e.
| Controller | Siemens F-CPU (S7-1500F, S7-1200F, ET 200SP F) |
| Hardware STO | Physical STO input still available, without PROFIsafe |
Downloads
Files by motor type
GSDML file - MAC Gen III
PROFIdrive telegrams 111 and 3, the JVL telegram, PROFIsafe module and start-up parameters.
PROFINET and PROFIdrive reference - MAC Gen III
Telegram layouts, control and status words, parameter access, LEDs.
GSDML file - Classic MAC and MIS / MIL
One file for MAC00-EP4 / EP41 modules and MIS / MIL motors with PROFINET.
JVL Profinet Library V1.2
Function blocks: JVL_MAC_Comms, _Position, _Velocity, _Jog, _Halt, _Disable, _Reset, JVL_MAC140_Home / JVL_MAC400_Home, and JVL_ReadWriteReg for any register. Includes an example.
PROFINET IO example - cyclic data, without library
For programmers who want to work directly with the motor registers.
PROFINET reference
Commissioning, DCP and naming, cyclic data, acyclic access and module registers.
GSDML file - MIS / MIL and Classic MAC
Same file as for Classic MAC.
JVL Profinet Library V1.2
JVL_MIS_Comms, _Position, _Velocity, _Jog, _Home (set position, home to sensor, home to end stop), _Halt, _Disable, _Reset, plus JVL_ReadWriteReg.
Example - two MIS motors over wireless PROFINET
Two MIS motors on a wireless access point. The same project works on a wired network.
Step 7 customer example - MIS34x
For Step 7 Classic users.
PROFINET reference
Commissioning, DCP and naming, cyclic data and register access.
Questions programmers usually ask
Do I need MacTalk?
MAC Gen III: no, setup is done in TIA Portal. MacTalk is useful for fine tuning, scope and diagnostics. Classic MAC and MIS: once per motor for the cyclic data setup, unless you write it from the PLC. Tasks that need MacTalk
Do I need a JVL library?
MAC Gen III with PROFIdrive: no. Use SINA_POS or the S7-1500 technology objects. Classic MAC and MIS: the JVL Profinet Library saves you writing the register handling.
Which telegram should I choose?
Keep the default telegram 111 for point-to-point moves. Choose telegram 3 if the axis is a technology object in an S7-1500, for example for gearing or cams. Control methods
How do I replace a motor in the field?
Plug in the new motor. With the topology configured in TIA Portal, the PLC names it and writes the parameters. Motor swap
Can I read a register that is not in the telegram?
Yes, by acyclic access. Classic MAC and MIS: JVL_ReadWriteReg in the JVL library. Only one acyclic request per network at a time; use a resource manager such as Siemens LAcycCom with many motors.
Can I use a ring?
Yes. The motors are MRP clients and the built-in switch lets you daisy-chain motor to motor.
Does it work with a KUKA robot controller?
Yes. Enable the alternative byte order (bit 12 in module register 6, or "Alt. byte order" in MacTalk) and save to flash.
Who do I call if I get stuck?
Your local JVL distributor, or JVL support: support@jvl.dk. Have the motor part number and serial number (on the label) ready.
PROFINET specifications
| Application protocol | PROFINET IO |
| Drive profile | MAC Gen III: PROFIdrive, telegrams 111 and 3 · Classic MAC, MIS: JVL telegram |
| Functional safety | MAC Gen III: PROFIsafe, SIL 3 / PL e |
| Conformance class | RT (Class 1) |
| Further protocols | DCP, LLDP, SNMP, CL-RPC, RTA, MRP client |
| Baud rate | 100 Mbit/s, full duplex |
| Cyclic data (JVL telegram) | Up to 8 read + 8 write words (32-bit) |
| Network minimum cycle time | 1 ms |
| Module minimum cycle time | MAC050-320: 4 ms (1/1 words), 20 ms (5/5), 32 ms (8/8) · MAC400-4500: 1 ms (1/1, 5/5), 1.2 ms (8/8) |
| Forwarding delay | 3.25 µs |
| Topology | Line, ring, tree, star · max. 100 m between devices |
| Standards | IEC 61158, IEC 61784 |
PROFINET by Motor Type
How PROFINET is implemented across the JVL motor families
| Specification | MAC + moduleMAC servo with MAC00-Ex4 expansion moduleMAC00-EP4 | MAC Gen IIIBuilt-in interfaceMAC404M2-GAAQEP2 | MIS with SMC66ServoStep integrated stepperMIS171S16EPH266 | MIS with SMC67ServoStep integrated stepperReference part number pending |
|---|---|---|---|---|
| Available | Yes | Yes | Yes | - |
| Application Protocol | Profinet IO | Profinet IO | Profinet IO | - |
| Company | Siemens | Siemens | Siemens | - |
| MacTalk over RS232 | Yes | Yes | Yes | - |
| IIoT, IoT, Industrie 4.0 | Yes | Yes | Yes | - |
| MacTalk over Ethernet | Yes | Yes | Yes | - |
| Scope | Yes | Yes | Planned | - |
| ePLC transfer | Yes | Yes | Yes | - |
| Load Default | Yes | Yes | Yes | - |
| Firmware Update | Yes | Yes | Yes | - |
| Transport Protocol | TCP/IP, UDP/IP, Profinet RT | TCP/IP, UDP/IP, Profinet RT | TCP/IP, UDP/IP, Profinet RT | - |
| Syncronization | Planned | Planned | Planned | - |
| Drive profile | Planned | Planned | Planned | - |
| Sync. Cycletimes | - | - | - | - |
| Sync. jitter | - | - | - | - |
| Network Minimum cycle time | 1 ms | 1 ms | 1 ms | - |
| Module Minimum cycle time: MAC050-320 | 4 ms at 1/1 20 ms at 5/5 32 ms at 8/8 *1) | 4 ms at 1/1 20 ms at 5/5 32 ms at 8/8 *1) | - | - |
| Module Minimum cycle time: MAC400-4500 | 1 ms at 1/1 1 ms at 5/5 1.2 ms at 8/8 | 1 ms at 1/1 1 ms at 5/5 1.2 ms at 8/8 | - | - |
| Address Range | 65535 | 65535 | 65535 | - |
| Max. Baudrate | Ethernet 100 Mbit/s | Ethernet 100 Mbit/s | Ethernet 100 Mbit/s | - |
| Forwarding delay | 3.25 µs | 3.25 µs | 3.25 µs | - |
| Network | Switches, routers, wireless | Switches, routers, wireless | Switches, routers, wireless | - |
| Standards | IEC 61158, IEC 61784 | IEC 61158, IEC 61784 | IEC 61158, IEC 61784 | - |
| Further supported protocols | RTC class 1-3, RTA, DCP, CL-RCP,LLDP, SNMP, MRP client | RTC class 1-3, RTA, DCP, CL-RCP,LLDP, SNMP, MRP client | RTC class 1-3, RTA, DCP, CL-RCP,LLDP, SNMP, MRP client | - |
| User org. | Profibus int. | Profibus int. | Profibus int. | - |
| User org. Link | www.profibus.com | www.profibus.com | www.profibus.com | - |
*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) NOT applicable for MAC050-MAC141. *3) IIoT: Industrial Internet of things, IoT: Internet of things. *4) Requirements: EtherCAT Master. *5) Connect to Sercos master when using ring topology otherwise connect to last motor in line.
*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) IIoT: Industrial Internet of things, IoT: Internet of things. *3) Requirements: EtherCAT Master. *4) Connect to Sercos master when using ring topology otherwise connect to last motor in line.
PROFINET servo and stepper motors from JVL
JVL integrated servo motors (MAC) and integrated stepper motors (MIS/MIL ServoStep) are available with PROFINET IO for Siemens S7-1200 and S7-1500 controllers and other PROFINET controllers. Each motor combines motor, encoder, drive and controller in one housing and connects directly to the network, with a built-in Ethernet switch for daisy-chaining and MRP ring support. MAC Gen III servo motors support the PROFIdrive drive profile, so they can be controlled from TIA Portal with SINA_POS or S7-1500 technology objects, and PROFIsafe for functional safety up to SIL 3 / PL e. JVL provides GSDML files, the JVL Profinet Library for TIA Portal and example projects.
PROFINET is the industrial Ethernet standard from PROFIBUS & PROFINET International (PI), defined in IEC 61158 and IEC 61784. It runs over standard 100 Mbit/s Ethernet and uses DCP for name and IP assignment and LLDP for topology detection, which allows device replacement without a programming device.
Help with your first motor
Your local JVL distributor or JVL support will help you get started.