Home / Protocols / PROFINET

PROFINET · PROFIdrive · PROFIsafe

PROFINET for JVL Servo & Stepper Motors

MAC Gen III runs as a standard PROFIdrive axis in TIA Portal, with PROFIsafe for safety over the same cable. Add the motor, pick the telegram, move it with Siemens' own blocks.

Find your filesChoose control method
PROFINET
PROFIdrive drive profile
PROFIsafe SIL 3 / PL e
3Motor families
PROFIdriveStandard telegrams, MAC Gen III
PROFIsafeSTO, SS1, SLS and more
MRPDaisy chain + ring

Overview

Motors and files at a glance

Check the part number on the motor label.

MotorRecognise it byGSDML fileControl from TIA PortalPROFIsafeProgram example
MAC Gen III servo
built-in PROFINET
EP in part no., e.g. MAC404M2-GAAQEP2GSDML 2026-10-01PROFIdrive: technology object or SINA_POS
or JVL telegram + JVL library
✓-
Classic MAC
servo motor with module
Module MAC00-EP4 / EP41 on the motorGSDML 2024-04-23JVL telegram (8 words) + JVL Profinet Library-TIA example
MIS / MIL stepper
closed-loop ServoStep
EP in part no., e.g. MIS171S16EPH266GSDML 2024-04-23JVL telegram (8 words) + JVL Profinet Library-Wireless example

Before you start

How JVL motors work on PROFINET

Motor + drive + controller

All built into the motor. Connect power and Ethernet directly and daisy-chain motor to motor through the built-in switch.

PROFINET IO device

Name of station and IP address are assigned by TIA Portal (DCP), like any other PROFINET device.

Gen III: a standard drive

PROFIdrive telegrams, so the S7 technology objects and Siemens' drive blocks work without a JVL library.

MacTalk

Gen III: optional, for tuning, scope and diagnostics. Classic MAC and MIS: needed once for the cyclic data setup. Tasks that need MacTalk

MAC Gen III

Choose your control method

Select the telegram when you add the motor in TIA Portal. The default needs no changes.

DEFAULT

Drive-based positioning

The motor runs the motion profile. The PLC sends target, speed and ramps with Siemens' SINA_POS block (FB284).

  • Telegram 111
  • S7-1200 and S7-1500
  • Lowest PLC load, simplest program
S7-1500 TO

Technology object

Add the motor as a positioning or synchronous axis and use the PLCopen blocks MC_Power, MC_Home, MC_MoveAbsolute.

  • Telegram 3 (speed + encoder)
  • Gearing and cam with S7-1500T
  • Absolute encoder position in the encoder word, no homing after power-up
JVL TELEGRAM

JVL registers

8 read and 8 write words, freely mapped to motor registers. Same as Classic MAC and MIS, with the JVL Profinet Library.

  • One PLC program for all JVL motors
  • Access to any motor register
  • Mapping set from TIA Portal

Quick start

First motor running

  1. Install the GSDML fileOptions → Manage general station description files. The motor appears under Other field devices → PROFINET IO → Drives → JVL.
  2. Add the motor and keep the default telegramTelegram 111 is preselected. Change it only if you use a technology object (telegram 3).
  3. Assign the device nameRight-click the motor → Assign device name. The PLC sets the IP address. No MacTalk needed.
  4. Set the motor parameters in TIA PortalIn the device properties: load factor, filter, direction and limits. The PLC writes them to the motor at every start-up.
  5. MoveCall SINA_POS, or MC_MoveAbsolute on the technology object.

Tasks that need MacTalk

MacTalk is JVL's PC software for tuning and diagnostics.

TaskMAC Gen IIIClassic MAC, MIS / MIL
Device name and IP addressTIA PortalTIA Portal or MacTalk
Select telegram / cyclic dataTIA PortalMacTalk, or from the PLC by acyclic write
Load factor, filter, limitsTIA PortalMacTalk
Program and run the motor from the PLCSiemens blocks or JVL libraryJVL library
Fine tuning, scope, diagnosticsMacTalkMacTalk
ePLC programming, firmware update, backupMacTalkMacTalk

Cyclic setup from the PLC

Classic MAC and MIS: write the cyclic setup to module registers 16-31, save to flash and restart the module. LB0056 section 6.5.8

Setup with MacTalk

Connect over Ethernet or the serial cable. Set the cyclic data in the Profinet tab and press Apply and save.

Benefits of MacTalk

  • Fast prototyping: run and tune the motor before the PLC program exists.
  • Scope: record position, velocity and torque.
  • ePLC: fast I/O-triggered tasks inside the motor.
  • Backup: save the full motor setup to a file.

Service

Swap a motor without a PC

A new motor from stock is named and configured by the PLC. The service technician only changes the motor.

1. Blank name at power-up

Factory default: the motor starts without a name of station, so the PLC can recognise it as new.

2. PLC names it by topology

Wire the ports in the Topology view in TIA Portal. The PLC gives the new motor the name of the port it is plugged into.

3. Parameters from the PLC

MAC Gen III: telegram and motor parameters are stored in the TIA project and written at start-up. The motor runs as the old one did.

MAC Gen III · Functional safety

PROFIsafe: safety over the same cable

MAC Gen III with PROFIsafe takes its safety commands from an F-CPU over PROFINET. No separate safety wiring to each motor, and safety functions beyond STO run in the motor itself.

Stopping functions

  • STO Safe Torque Off
  • SS1 Safe Stop 1
  • SS2 Safe Stop 2

Monitoring functions

  • SLS Safely Limited Speed
  • SOS Safe Operating Stop
  • SSM Safe Speed Monitor
  • SDI Safe Direction
  • SLP Safely Limited Position

Output functions

  • SBC Safe Brake Control

All functions: SIL 3 / PL e.

ControllerSiemens F-CPU (S7-1500F, S7-1200F, ET 200SP F)
Hardware STOPhysical STO input still available, without PROFIsafe

Downloads

Files by motor type

GSDML

GSDML file - MAC Gen III

GSDML-V2.45-JVL-MAC-20261001.zip · motor firmware 3.01.04 (2026-11-19)

PROFIdrive telegrams 111 and 3, the JVL telegram, PROFIsafe module and start-up parameters.

You need it: once per TIA Portal installation.
MANUAL

PROFINET and PROFIdrive reference - MAC Gen III

MAC User Manual LB0067

Telegram layouts, control and status words, parameter access, LEDs.

You need it: when you go beyond the default telegram.

Questions programmers usually ask

Do I need MacTalk?

MAC Gen III: no, setup is done in TIA Portal. MacTalk is useful for fine tuning, scope and diagnostics. Classic MAC and MIS: once per motor for the cyclic data setup, unless you write it from the PLC. Tasks that need MacTalk

Do I need a JVL library?

MAC Gen III with PROFIdrive: no. Use SINA_POS or the S7-1500 technology objects. Classic MAC and MIS: the JVL Profinet Library saves you writing the register handling.

Which telegram should I choose?

Keep the default telegram 111 for point-to-point moves. Choose telegram 3 if the axis is a technology object in an S7-1500, for example for gearing or cams. Control methods

How do I replace a motor in the field?

Plug in the new motor. With the topology configured in TIA Portal, the PLC names it and writes the parameters. Motor swap

Can I read a register that is not in the telegram?

Yes, by acyclic access. Classic MAC and MIS: JVL_ReadWriteReg in the JVL library. Only one acyclic request per network at a time; use a resource manager such as Siemens LAcycCom with many motors.

Can I use a ring?

Yes. The motors are MRP clients and the built-in switch lets you daisy-chain motor to motor.

Does it work with a KUKA robot controller?

Yes. Enable the alternative byte order (bit 12 in module register 6, or "Alt. byte order" in MacTalk) and save to flash.

Who do I call if I get stuck?

Your local JVL distributor, or JVL support: support@jvl.dk. Have the motor part number and serial number (on the label) ready.

PROFINET specifications

Application protocolPROFINET IO
Drive profileMAC Gen III: PROFIdrive, telegrams 111 and 3 · Classic MAC, MIS: JVL telegram
Functional safetyMAC Gen III: PROFIsafe, SIL 3 / PL e
Conformance classRT (Class 1)
Further protocolsDCP, LLDP, SNMP, CL-RPC, RTA, MRP client
Baud rate100 Mbit/s, full duplex
Cyclic data (JVL telegram)Up to 8 read + 8 write words (32-bit)
Network minimum cycle time1 ms
Module minimum cycle timeMAC050-320: 4 ms (1/1 words), 20 ms (5/5), 32 ms (8/8) · MAC400-4500: 1 ms (1/1, 5/5), 1.2 ms (8/8)
Forwarding delay3.25 µs
TopologyLine, ring, tree, star · max. 100 m between devices
StandardsIEC 61158, IEC 61784

PROFINET by Motor Type

How PROFINET is implemented across the JVL motor families

SpecificationMAC + moduleMAC servo with MAC00-Ex4 expansion moduleMAC00-EP4MAC Gen IIIBuilt-in interfaceMAC404M2-GAAQEP2MIS with SMC66ServoStep integrated stepperMIS171S16EPH266MIS with SMC67ServoStep integrated stepperReference part number pending
AvailableYesYesYes-
Application ProtocolProfinet IOProfinet IOProfinet IO-
CompanySiemensSiemensSiemens-
MacTalk over RS232YesYesYes-
IIoT, IoT, Industrie 4.0YesYesYes-
MacTalk over EthernetYesYesYes-
ScopeYesYesPlanned-
ePLC transferYesYesYes-
Load DefaultYesYesYes-
Firmware UpdateYesYesYes-
Transport ProtocolTCP/IP, UDP/IP, Profinet RTTCP/IP, UDP/IP, Profinet RTTCP/IP, UDP/IP, Profinet RT-
SyncronizationPlannedPlannedPlanned-
Drive profilePlannedPlannedPlanned-
Sync. Cycletimes----
Sync. jitter----
Network Minimum cycle time1 ms1 ms1 ms-
Module Minimum cycle time: MAC050-3204 ms at 1/1 20 ms at 5/5 32 ms at 8/8 *1)4 ms at 1/1 20 ms at 5/5 32 ms at 8/8 *1)--
Module Minimum cycle time: MAC400-45001 ms at 1/1 1 ms at 5/5 1.2 ms at 8/81 ms at 1/1 1 ms at 5/5 1.2 ms at 8/8--
Address Range655356553565535-
Max. BaudrateEthernet 100 Mbit/sEthernet 100 Mbit/sEthernet 100 Mbit/s-
Forwarding delay3.25 µs3.25 µs3.25 µs-
NetworkSwitches, routers, wirelessSwitches, routers, wirelessSwitches, routers, wireless-
StandardsIEC 61158, IEC 61784IEC 61158, IEC 61784IEC 61158, IEC 61784-
Further supported protocolsRTC class 1-3, RTA, DCP, CL-RCP,LLDP, SNMP, MRP clientRTC class 1-3, RTA, DCP, CL-RCP,LLDP, SNMP, MRP clientRTC class 1-3, RTA, DCP, CL-RCP,LLDP, SNMP, MRP client-
User org.Profibus int.Profibus int.Profibus int.-
User org. Linkwww.profibus.comwww.profibus.comwww.profibus.com-
MAC + module · MAC Gen III

*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) NOT applicable for MAC050-MAC141. *3) IIoT: Industrial Internet of things, IoT: Internet of things. *4) Requirements: EtherCAT Master. *5) Connect to Sercos master when using ring topology otherwise connect to last motor in line.

MIS with SMC66

*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) IIoT: Industrial Internet of things, IoT: Internet of things. *3) Requirements: EtherCAT Master. *4) Connect to Sercos master when using ring topology otherwise connect to last motor in line.

PROFINET servo and stepper motors from JVL

JVL integrated servo motors (MAC) and integrated stepper motors (MIS/MIL ServoStep) are available with PROFINET IO for Siemens S7-1200 and S7-1500 controllers and other PROFINET controllers. Each motor combines motor, encoder, drive and controller in one housing and connects directly to the network, with a built-in Ethernet switch for daisy-chaining and MRP ring support. MAC Gen III servo motors support the PROFIdrive drive profile, so they can be controlled from TIA Portal with SINA_POS or S7-1500 technology objects, and PROFIsafe for functional safety up to SIL 3 / PL e. JVL provides GSDML files, the JVL Profinet Library for TIA Portal and example projects.

PROFINET is the industrial Ethernet standard from PROFIBUS & PROFINET International (PI), defined in IEC 61158 and IEC 61784. It runs over standard 100 Mbit/s Ethernet and uses DCP for name and IP assignment and LLDP for topology detection, which allows device replacement without a programming device.

Help with your first motor

Your local JVL distributor or JVL support will help you get started.

Find a Distributor

Contact Support

Report a problem or suggest a feature

Tell us what went wrong or what you are missing. The page you are on is sent with your message.

What kind of report?