Modbus TCP by Motor Type
Industrial Ethernet is the name given to the use of the Ethernet network protocol in an industrial environment, for automation and process control.
A number of techniques are used to adapt the Ethernet protocol for the needs of industrial processes, which must provide real time behavior.
By using non-proprietary protocols, automation systems from different manufacturers can be interconnected throughout a process plant.
Industrial Ethernet takes advantage of the relatively larger marketplace for computer interconnections to reduce cost and improve performance of communications between industrial controllers.
Industrial Ethernet (IE) components used in plant process areas must be designed to work in harsh environments of temperature extremes, humidity, and vibration that exceed the ranges for IT equipment intended for installation in controlled environments.
| Specification | MAC + moduleMAC servo with MAC00-Ex4 expansion moduleMAC00-EM4 | MAC Gen IIIBuilt-in interfaceMAC404M2-GAAQEM2 | MIS with SMC66ServoStep integrated stepperMIS171S16EMH266 | MIS with SMC67ServoStep integrated stepperReference part number pending |
|---|---|---|---|---|
| Downloads - latest version | ||||
| PLC demo program | ||||
| Available | Yes | Yes | Yes | - |
| Application Protocol | Modbus | Modbus | Modbus | - |
| Company | - | - | 0 | - |
| MacTalk over RS232 | Yes | Yes | Yes | - |
| IIoT, IoT, Industrie 4.0 | Yes | Yes | Yes | - |
| MacTalk over Ethernet | Yes | Yes | Yes | - |
| Scope | Yes | Yes | Planned | - |
| ePLC transfer | Yes | Yes | Yes | - |
| Load Default | Yes | Yes | Yes | - |
| Firmware Update | Yes | Yes | Yes | - |
| Transport Protocol | TCP/IP or UDP/IP | TCP/IP or UDP/IP | TCP/IP, UDP/IP | - |
| Syncronization | - | - | - | - |
| Drive profile | - | - | - | - |
| Sync. Cycletimes | - | - | - | - |
| Sync. jitter | - | - | - | - |
| Network Minimum cycle time | ~2 ms | ~2 ms | ~2 ms | - |
| Module Minimum cycle time: MAC050-320 | Not Cyclic: 1 reg. 2 ms, 10 reg. 20 ms | Not Cyclic: 1 reg. 2 ms, 10 reg. 20 ms | - | - |
| Module Minimum cycle time: MAC400-4500 | Not Cyclic: 1 reg. 2 ms, 10 reg. 4 ms | Not Cyclic: 1 reg. 2 ms, 10 reg. 4 ms | - | - |
| Address Range | 65535 | 65535 | 65535 | - |
| Max. Baudrate | Ethernet 100 Mbit/s | Ethernet 100 Mbit/s | Ethernet 100 Mbit/s | - |
| Forwarding delay | 10-130 µs | 10-130 µs | 10-130 µs | - |
| Network | Switches, routers, wireless | Switches, routers, wireless | Switches, routers, wireless | - |
| Standards | IEC 61158, IEC 61784 | IEC 61158, IEC 61784 | IEC 61158, IEC 61784 | - |
| Further supported protocols | DHCP | DHCP | DHCP | - |
| User org. | Modbus Org. | Modbus Org. | Modbus Org. | - |
| User org. Link | www.modbus.org | www.modbus.org | www.modbus.org | - |
*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) NOT applicable for MAC050-MAC141. *3) IIoT: Industrial Internet of things, IoT: Internet of things. *4) Requirements: EtherCAT Master. *5) Connect to Sercos master when using ring topology otherwise connect to last motor in line.
*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8. *2) IIoT: Industrial Internet of things, IoT: Internet of things. *3) Requirements: EtherCAT Master. *4) Connect to Sercos master when using ring topology otherwise connect to last motor in line.