PA0190 IO gateway for MACmotor and MISmotor with 17pin connector

Contact Us

The gateway split the 17 pin connector into 4pcs M12 connectors with different functions:

COMMACtalk or RS232 (MAC) and RS485(MIS) serial interface and some IOA
IO1For local input/output/zero search switch or limit sensors
IO2For local input/output/zero search switch or limit sensors
BypassRS422 for eg local encoder or pass through if signals should be directed to the control cabinet

COM MACtalk or RS232 (MAC) and RS485(MIS) serial interface and some IOA IO1 For local input/output/zero search switch or limit sensors IO2 For local input/output/zero search switch or limit sensors Bypass RS422 for eg local encoder or pass through if signals should be directed to the control cabinet COM MACtalk or RS232 (MAC) and RS485(MIS) serial interface and some IOA IO1 For local input/output/zero search switch or limit sensors IO2 For local input/output/zero search switch or limit sensors Bypass RS422 for eg local encoder or pass through if signals should be directed to the control cabinet

COM MACtalk or RS232 (MAC) and RS485(MIS) serial interface and some IOA IO1 For local input/output/zero search switch or limit sensors IO2 For local input/output/zero search switch or limit sensors Bypass RS422 for eg local encoder or pass through if signals should be directed to the control cabinet COM MACtalk or RS232 (MAC) and RS485(MIS) serial interface and some IOA IO1 For local input/output/zero search switch or limit sensors IO2 For local input/output/zero search switch or limit sensors Bypass RS422 for eg local encoder or pass through if signals should be directed to the control cabinet

Thereby can local machine IO be connected directly to the integrated motor without passing through the control cabinet. The gateway are a perfect solution for harsh industrial environments. Fully molded and assembled with M12 connectors it is IP67 compliant to resist the most extreme conditions. It enables cabinet installations to be shifted into the field for operation in tough environment such as high humidity or hazardous areas.

DETAILED - EXAMPLES OF APPLICATIONS - ACCESSORIES- SCHEMATIC DIAGRAM - CONNECTOR DESCRIPTION for MAC and MISDOWNLOAD - DATASHEET - BROCHURE - USER MANUAL - CAD FILES

Downloads & Resources

Datasheets

Firmware

ZIP
CANopenExplorer V2.2
CANopenExplorer version 2.2. is a program that was developed for internal use only, but the program has features that are nice to have, and make it more easy to start up the MAC motor when this is equipped with a MAC00-F
ZIP
MAC00-ECx_V3_54.zip
MIS17/23/34/43 and -ECx modules (8/4-2024) Version 3.54 MAC00-ECx_V3_54.zip
PDF
MAC00-ECx_V3_54.zip
MIS17/23/34/43 and -ECx modules (8/4-2024) Version 3.54 MAC00-ECx_V3_54.zip
ZIP
MAC00-EIx_V3_44.zip
MIS17/23/34/43 and -EIx modules (4/4-2025) Version 3.44 MAC00-EIx_V3_44.zip
PDF
MAC00-EIx_V3_44.zip
MIS17/23/34/43 and -EIx modules (4/4-2025) Version 3.44 MAC00-EIx_V3_44.zip
ZIP
MAC00-ELx_V3_12.zip
MIS17/23/34/43 and -ELx modules (8/4-2024) Version 3.12 MAC00-ELx_V3_12.zip
PDF
MAC00-ELx_V3_12.zip
MIS17/23/34/43 and -ELx modules (8/4-2024) Version 3.12 MAC00-ELx_V3_12.zip
ZIP
MAC00-EMx_V3_28.zip
MIS17/23/34/43 and -EMx modules (4/4-2025) Version 3.28 MAC00-EMx_V3_28.zip
PDF
MAC00-EMx_V3_28.zip
MIS17/23/34/43 and -EMx modules (4/4-2025) Version 3.28 MAC00-EMx_V3_28.zip
ZIP
MAC00-EPx_V3_42.zip
MIS17/23/34/43 and -EPx modules (8/11-2023) Version 3.42 MAC00-EPx_V3_42.zip
PDF
MAC00-EPx_V3_42.zip
MIS17/23/34/43 and -EPx modules (8/11-2023) Version 3.42 MAC00-EPx_V3_42.zip
ZIP
MAC00-ESx_V3_16.zip
MIS17/23/34/43 and -ESx modules (8/4-2024) Version 3.16 MAC00-ESx_V3_16.zip
PDF
MAC00-ESx_V3_16.zip
MIS17/23/34/43 and -ESx modules (8/4-2024) Version 3.16 MAC00-ESx_V3_16.zip
ZIP
MAC00-FCx_v3_05.zip
Firmware for MAC00-FCx modules (x/x-20xx) EDS-file for MAC050-141 (-A) EDS-file for MAC400+ and Version 3.05 (ModBus supported) mac00-fc-SMAC mac00.fc-BMAC MAC00-FCx_v3_05.zip *
ZIP
MAC00-FDx_v3_00.zip
Firmware for MAC00-FDx modules (x/x-20xx) Version 3.0 (Modbus supported) MAC00-FDx_v3_00.zip
ZIP
MAC00-FP_v2_02HS.zip
Firmware for MAC00-FP modules (x/x-20xx) Version 3.04 (ModBus supported) Uses motor address Version 3.05 (Modbus supported) Uses dip-sw. at module Version 2.02HS MAC00-FP_v3_04.zip MAC00-FP_v3_05.zip MAC00-FP_v2_02HS.zip
ZIP
MAC00-FP_v3_04.zip
Firmware for MAC00-FP modules (x/x-20xx) Version 3.04 (ModBus supported) Uses motor address Version 3.05 (Modbus supported) Uses dip-sw. at module Version 2.02HS MAC00-FP_v3_04.zip MAC00-FP_v3_05.zip MAC00-FP_v2_02HS.zip
ZIP
MAC00-FP_v3_05.zip
Firmware for MAC00-FP modules (x/x-20xx) Version 3.04 (ModBus supported) Uses motor address Version 3.05 (Modbus supported) Uses dip-sw. at module Version 2.02HS MAC00-FP_v3_04.zip MAC00-FP_v3_05.zip MAC00-FP_v2_02HS.zip
ZIP
MAC00-FSx_v2_05.zip
Firmware for MAC00-FSx Version 2.05 (19/2-2019) Version 2.06 (10/4-2025) MAC00-FSx_v2_05.zip MAC00-FSx_v2_06.zip
ZIP
MAC00-FSx_v2_06.zip
Firmware for MAC00-FSx Version 2.05 (19/2-2019) Version 2.06 (10/4-2025) MAC00-FSx_v2_05.zip MAC00-FSx_v2_06.zip
ZIP
MAC00-Rx_v2_03.zip
Firmware for MAC00-Rx modules (x/x-2019) Version 2.03 MAC00-Rx_v2_03.zip
ZIP
MAC00-RxP_v3_01.zip
Firmware for MAC00-RxP modules (x/x-20xx) Version 3.01 MAC00-RxP_v3_01.zip

Config Files

ZIP
EtherNet/IP AOIs - Classic MAC with module
Add On Instructions for MAC-Motors
Download
ZIP
CANopen EDS file for MAC00-FCx
CANOpen EDS file for MAC00-FCxx modules This file covers MAC50-A to MAC141-A with firmware version 7.15 and later
Download
ZIP
DeviceNet EDS file for MAC00-FDx (Version 1.0)Download
ZIP
EtherNet/IP EDS file - Classic MAC with module
For MAC Integrated Servo Motors with Ethernet Module
Download
ZIP
EtherCAT ESI file - Classic MAC with module and MIS (version 26)
EtherCAT slave information file. JVL ECS V26. ( 20/5-2022 )
Download
ZIP
PROFIBUS GSD file (JVLI06BC)
Profibus GSD-file for MAC00-FPx modules (Version 1.2) JVLI06BC.zip
Download
ZIP
PROFINET GSDML file - Classic MAC and MIS / MIL (2024-04-23)
GSD file - 8 regs. PZD (2024-04-23 - From FW 3.40)
Download
ZIP
Powerlink MAC050-141, 5 regs - XDD fileDownload
ZIP
Powerlink MAC050-141, 8 regs - XDD fileDownload
ZIP
Powerlink MAC400+, 5 regs - XDD fileDownload
ZIP
Powerlink MAC400+, 8 regs - XDD fileDownload
ZIP
JVL Profinet Library V1.2 for TIA Portal
PROFINET IO example for TIA V14 or higher using funtion blocks. (JVL Profinet Library V1.2.zip)
Download

General

PDF
SCHEMATIC DIAGRAMDownload
PDF
CONNECTOR DESCRIPTIONfor MAC and MISDownload
PDF
PA0190..
Junction Box JVL Type No. 2D (DWG) 2D (DXF) 3D (IGES) 3D (STEP) PDF l 17T01NMB 17pin male connector for MIS WI1302.. PA0190 PA0190