PA0190 IO gateway for MACmotor and MISmotor with 17pin connector
The gateway split the 17 pin connector into 4pcs M12 connectors with different functions:
| COM | MACtalk or RS232 (MAC) and RS485(MIS) serial interface and some IOA |
| IO1 | For local input/output/zero search switch or limit sensors |
| IO2 | For local input/output/zero search switch or limit sensors |
| Bypass | RS422 for eg local encoder or pass through if signals should be directed to the control cabinet |
COM MACtalk or RS232 (MAC) and RS485(MIS) serial interface and some IOA IO1 For local input/output/zero search switch or limit sensors IO2 For local input/output/zero search switch or limit sensors Bypass RS422 for eg local encoder or pass through if signals should be directed to the control cabinet COM MACtalk or RS232 (MAC) and RS485(MIS) serial interface and some IOA IO1 For local input/output/zero search switch or limit sensors IO2 For local input/output/zero search switch or limit sensors Bypass RS422 for eg local encoder or pass through if signals should be directed to the control cabinet
COM MACtalk or RS232 (MAC) and RS485(MIS) serial interface and some IOA IO1 For local input/output/zero search switch or limit sensors IO2 For local input/output/zero search switch or limit sensors Bypass RS422 for eg local encoder or pass through if signals should be directed to the control cabinet COM MACtalk or RS232 (MAC) and RS485(MIS) serial interface and some IOA IO1 For local input/output/zero search switch or limit sensors IO2 For local input/output/zero search switch or limit sensors Bypass RS422 for eg local encoder or pass through if signals should be directed to the control cabinet
Thereby can local machine IO be connected directly to the integrated motor without passing through the control cabinet. The gateway are a perfect solution for harsh industrial environments. Fully molded and assembled with M12 connectors it is IP67 compliant to resist the most extreme conditions. It enables cabinet installations to be shifted into the field for operation in tough environment such as high humidity or hazardous areas.
| DETAILED - EXAMPLES OF APPLICATIONS - ACCESSORIES | - SCHEMATIC DIAGRAM - CONNECTOR DESCRIPTION for MAC and MIS | DOWNLOAD - DATASHEET - BROCHURE - USER MANUAL - CAD FILES |
Downloads & Resources
Firmware
| CANopenExplorer V2.2 CANopenExplorer version 2.2. is a program that was developed for internal use only, but the program has features that are nice to have, and make it more easy to start up the MAC motor when this is equipped with a MAC00-F | ||
| MAC00-ECx_V3_54.zip MIS17/23/34/43 and -ECx modules (8/4-2024) Version 3.54 MAC00-ECx_V3_54.zip | ||
| MAC00-ECx_V3_54.zip MIS17/23/34/43 and -ECx modules (8/4-2024) Version 3.54 MAC00-ECx_V3_54.zip | ||
| MAC00-EIx_V3_44.zip MIS17/23/34/43 and -EIx modules (4/4-2025) Version 3.44 MAC00-EIx_V3_44.zip | ||
| MAC00-EIx_V3_44.zip MIS17/23/34/43 and -EIx modules (4/4-2025) Version 3.44 MAC00-EIx_V3_44.zip | ||
| MAC00-ELx_V3_12.zip MIS17/23/34/43 and -ELx modules (8/4-2024) Version 3.12 MAC00-ELx_V3_12.zip | ||
| MAC00-ELx_V3_12.zip MIS17/23/34/43 and -ELx modules (8/4-2024) Version 3.12 MAC00-ELx_V3_12.zip | ||
| MAC00-EMx_V3_28.zip MIS17/23/34/43 and -EMx modules (4/4-2025) Version 3.28 MAC00-EMx_V3_28.zip | ||
| MAC00-EMx_V3_28.zip MIS17/23/34/43 and -EMx modules (4/4-2025) Version 3.28 MAC00-EMx_V3_28.zip | ||
| MAC00-EPx_V3_42.zip MIS17/23/34/43 and -EPx modules (8/11-2023) Version 3.42 MAC00-EPx_V3_42.zip | ||
| MAC00-EPx_V3_42.zip MIS17/23/34/43 and -EPx modules (8/11-2023) Version 3.42 MAC00-EPx_V3_42.zip | ||
| MAC00-ESx_V3_16.zip MIS17/23/34/43 and -ESx modules (8/4-2024) Version 3.16 MAC00-ESx_V3_16.zip | ||
| MAC00-ESx_V3_16.zip MIS17/23/34/43 and -ESx modules (8/4-2024) Version 3.16 MAC00-ESx_V3_16.zip | ||
| MAC00-FCx_v3_05.zip Firmware for MAC00-FCx modules (x/x-20xx) EDS-file for MAC050-141 (-A) EDS-file for MAC400+ and Version 3.05 (ModBus supported) mac00-fc-SMAC mac00.fc-BMAC MAC00-FCx_v3_05.zip * | ||
| MAC00-FDx_v3_00.zip Firmware for MAC00-FDx modules (x/x-20xx) Version 3.0 (Modbus supported) MAC00-FDx_v3_00.zip | ||
| MAC00-FP_v2_02HS.zip Firmware for MAC00-FP modules (x/x-20xx) Version 3.04 (ModBus supported) Uses motor address Version 3.05 (Modbus supported) Uses dip-sw. at module Version 2.02HS MAC00-FP_v3_04.zip MAC00-FP_v3_05.zip MAC00-FP_v2_02HS.zip | ||
| MAC00-FP_v3_04.zip Firmware for MAC00-FP modules (x/x-20xx) Version 3.04 (ModBus supported) Uses motor address Version 3.05 (Modbus supported) Uses dip-sw. at module Version 2.02HS MAC00-FP_v3_04.zip MAC00-FP_v3_05.zip MAC00-FP_v2_02HS.zip | ||
| MAC00-FP_v3_05.zip Firmware for MAC00-FP modules (x/x-20xx) Version 3.04 (ModBus supported) Uses motor address Version 3.05 (Modbus supported) Uses dip-sw. at module Version 2.02HS MAC00-FP_v3_04.zip MAC00-FP_v3_05.zip MAC00-FP_v2_02HS.zip | ||
| MAC00-FSx_v2_05.zip Firmware for MAC00-FSx Version 2.05 (19/2-2019) Version 2.06 (10/4-2025) MAC00-FSx_v2_05.zip MAC00-FSx_v2_06.zip | ||
| MAC00-FSx_v2_06.zip Firmware for MAC00-FSx Version 2.05 (19/2-2019) Version 2.06 (10/4-2025) MAC00-FSx_v2_05.zip MAC00-FSx_v2_06.zip | ||
| MAC00-Rx_v2_03.zip Firmware for MAC00-Rx modules (x/x-2019) Version 2.03 MAC00-Rx_v2_03.zip | ||
| MAC00-RxP_v3_01.zip Firmware for MAC00-RxP modules (x/x-20xx) Version 3.01 MAC00-RxP_v3_01.zip |
Config Files
General
| SCHEMATIC DIAGRAM | Download | |
| CONNECTOR DESCRIPTIONfor MAC and MIS | Download | |
| PA0190.. Junction Box JVL Type No. 2D (DWG) 2D (DXF) 3D (IGES) 3D (STEP) PDF l 17T01NMB 17pin male connector for MIS WI1302.. PA0190 PA0190 |