High-speed MODBUS with integrated servo motors MAC050-141, -083, -320, MAC400-4500 and the stepper controllers SMC66/75/85 and integrated stepper motors MIS17x/-23x/-34x from JVL

JVL Industri Elektronik A/S, a world leader in integrated servo an stepper motors, offers another feature: The firmware supports the MODBUS RTU protocol.

The implementation supports the Read Holding Registers and Write Multiple Registers commands, which will give R/W access to all motor registers at speeds up to 1 Mbit/s, though typically the PC standard rates of 9600..115200 and 230400 bits/s would be used.

The implementation uses the original V1.1 version of the MODBUS protocol for maximum compatibility. The firmware supports the commonly used two-wire RS-485 as well as both the four-wire RS-485 and RS422 standards. Both the inexpensive MAC00-Bx and the advanced MAC00-FSx expansion modules allow access to these options.

MODBUS is generally considered the most widely used serial communications protocol in the industry.

For more information about MULTIBUS, click here.

 For more information about MODBUS for:

For more information about MAC1500-3000 click here.

For more information about MAC800 click here.

For more information about MAC400click here. For more information about SMC75click here.

Siemens S7 MODBUS Master/Slave description click here.

Downloads & Resources

Firmware

ZIP
CANopenExplorer V2.2
CANopenExplorer version 2.2. is a program that was developed for internal use only, but the program has features that are nice to have, and make it more easy to start up the MAC motor when this is equipped with a MAC00-F
ZIP
MAC00-ECx_V3_54.zip
MIS17/23/34/43 and -ECx modules (8/4-2024) Version 3.54 MAC00-ECx_V3_54.zip
PDF
MAC00-ECx_V3_54.zip
MIS17/23/34/43 and -ECx modules (8/4-2024) Version 3.54 MAC00-ECx_V3_54.zip
ZIP
MAC00-EIx_V3_44.zip
MIS17/23/34/43 and -EIx modules (4/4-2025) Version 3.44 MAC00-EIx_V3_44.zip
PDF
MAC00-EIx_V3_44.zip
MIS17/23/34/43 and -EIx modules (4/4-2025) Version 3.44 MAC00-EIx_V3_44.zip
ZIP
MAC00-ELx_V3_12.zip
MIS17/23/34/43 and -ELx modules (8/4-2024) Version 3.12 MAC00-ELx_V3_12.zip
PDF
MAC00-ELx_V3_12.zip
MIS17/23/34/43 and -ELx modules (8/4-2024) Version 3.12 MAC00-ELx_V3_12.zip
ZIP
MAC00-EMx_V3_28.zip
MIS17/23/34/43 and -EMx modules (4/4-2025) Version 3.28 MAC00-EMx_V3_28.zip
PDF
MAC00-EMx_V3_28.zip
MIS17/23/34/43 and -EMx modules (4/4-2025) Version 3.28 MAC00-EMx_V3_28.zip
ZIP
MAC00-EPx_V3_42.zip
MIS17/23/34/43 and -EPx modules (8/11-2023) Version 3.42 MAC00-EPx_V3_42.zip
PDF
MAC00-EPx_V3_42.zip
MIS17/23/34/43 and -EPx modules (8/11-2023) Version 3.42 MAC00-EPx_V3_42.zip
ZIP
MAC00-ESx_V3_16.zip
MIS17/23/34/43 and -ESx modules (8/4-2024) Version 3.16 MAC00-ESx_V3_16.zip
PDF
MAC00-ESx_V3_16.zip
MIS17/23/34/43 and -ESx modules (8/4-2024) Version 3.16 MAC00-ESx_V3_16.zip
ZIP
MAC00-FCx_v3_05.zip
Firmware for MAC00-FCx modules (x/x-20xx) EDS-file for MAC050-141 (-A) EDS-file for MAC400+ and Version 3.05 (ModBus supported) mac00-fc-SMAC mac00.fc-BMAC MAC00-FCx_v3_05.zip *
ZIP
MAC00-FDx_v3_00.zip
Firmware for MAC00-FDx modules (x/x-20xx) Version 3.0 (Modbus supported) MAC00-FDx_v3_00.zip
ZIP
MAC00-FP_v2_02HS.zip
Firmware for MAC00-FP modules (x/x-20xx) Version 3.04 (ModBus supported) Uses motor address Version 3.05 (Modbus supported) Uses dip-sw. at module Version 2.02HS MAC00-FP_v3_04.zip MAC00-FP_v3_05.zip MAC00-FP_v2_02HS.zip
ZIP
MAC00-FP_v3_04.zip
Firmware for MAC00-FP modules (x/x-20xx) Version 3.04 (ModBus supported) Uses motor address Version 3.05 (Modbus supported) Uses dip-sw. at module Version 2.02HS MAC00-FP_v3_04.zip MAC00-FP_v3_05.zip MAC00-FP_v2_02HS.zip
ZIP
MAC00-FP_v3_05.zip
Firmware for MAC00-FP modules (x/x-20xx) Version 3.04 (ModBus supported) Uses motor address Version 3.05 (Modbus supported) Uses dip-sw. at module Version 2.02HS MAC00-FP_v3_04.zip MAC00-FP_v3_05.zip MAC00-FP_v2_02HS.zip
ZIP
MAC00-FSx_v2_05.zip
Firmware for MAC00-FSx Version 2.05 (19/2-2019) Version 2.06 (10/4-2025) MAC00-FSx_v2_05.zip MAC00-FSx_v2_06.zip
ZIP
MAC00-FSx_v2_06.zip
Firmware for MAC00-FSx Version 2.05 (19/2-2019) Version 2.06 (10/4-2025) MAC00-FSx_v2_05.zip MAC00-FSx_v2_06.zip
ZIP
MAC00-Rx_v2_03.zip
Firmware for MAC00-Rx modules (x/x-2019) Version 2.03 MAC00-Rx_v2_03.zip
ZIP
MAC00-RxP_v3_01.zip
Firmware for MAC00-RxP modules (x/x-20xx) Version 3.01 MAC00-RxP_v3_01.zip

Config Files

ZIP
EtherNet/IP AOIs - Classic MAC with module
Add On Instructions for MAC-Motors
Download
ZIP
CANopen EDS file for MAC00-FCx
CANOpen EDS file for MAC00-FCxx modules This file covers MAC50-A to MAC141-A with firmware version 7.15 and later
Download
ZIP
DeviceNet EDS file for MAC00-FDx (Version 1.0)Download
ZIP
EtherNet/IP EDS file - Classic MAC with module
For MAC Integrated Servo Motors with Ethernet Module
Download
ZIP
EtherCAT ESI file - Classic MAC with module and MIS (version 26)
EtherCAT slave information file. JVL ECS V26. ( 20/5-2022 )
Download
ZIP
PROFIBUS GSD file (JVLI06BC)
Profibus GSD-file for MAC00-FPx modules (Version 1.2) JVLI06BC.zip
Download
ZIP
PROFINET GSDML file - Classic MAC and MIS / MIL (2024-04-23)
GSD file - 8 regs. PZD (2024-04-23 - From FW 3.40)
Download
ZIP
Powerlink MAC050-141, 5 regs - XDD fileDownload
ZIP
Powerlink MAC050-141, 8 regs - XDD fileDownload
ZIP
Powerlink MAC400+, 5 regs - XDD fileDownload
ZIP
Powerlink MAC400+, 8 regs - XDD fileDownload
ZIP
JVL Profinet Library V1.2 for TIA Portal
PROFINET IO example for TIA V14 or higher using funtion blocks. (JVL Profinet Library V1.2.zip)
Download

Report a problem or suggest a feature

Tell us what went wrong or what you are missing. The page you are on is sent with your message.

What kind of report?