Key Features

  • ✓RS232 interface
  • ✓Fieldbus slave address set on dip-switch
  • ✓DIN rail mounting
  • ✓10-30 VDC operation
  • ✓Compact unit which is easily mounted
  • ✓LED indication for Power, Ready, Busy RS232/Fieldbus
  • ✓Differential bus interfaces with opto-couplers
  • ✓DSUB and Combicon connectors
  • ✓Dual port RAM for exchange of data
  • ✓Can be connected to JVL Controllers AMC1x, AMC2x,SMC2x, DMC10 and Indexer SMI3x
Contact Us
Note: Not for new developments

The FBG series of gateways is used to interface different fieldbus systems, such as Profibus etc., to JVL units equipped with an RS232 interface. They thus function as gateways between a fieldbus and the RS232, translating commands bidirectionally between the two systems. In this way it is possible for example to use a PLC to control velocities, displacement and register contents directly from a fieldbus, and to read error codes, position, register contents, inputs and outputs from connected JVL modules. Important operating parameters, I/O status, etc., are continuously monitored by the FBG10 and can therefore be quickly read by the fieldbus. The FBG10 series of Field Bus Gateways thus provides an inexpensive solution for applications that use a fieldbus together with JVL modules which only have an RS232 interface. Customised models of the FBG10 can also be produced for RS232 protocols other than JVL´s own.

DETAILED - APPLICATIONSDOWNLOAD - DATASHEET - USER MANUAL - FBG10 Profibus module

Downloads & Resources

Firmware

ZIP
CANopenExplorer V2.2
CANopenExplorer version 2.2. is a program that was developed for internal use only, but the program has features that are nice to have, and make it more easy to start up the MAC motor when this is equipped with a MAC00-F
ZIP
MAC00-ECx_V3_54.zip
MIS17/23/34/43 and -ECx modules (8/4-2024) Version 3.54 MAC00-ECx_V3_54.zip
PDF
MAC00-ECx_V3_54.zip
MIS17/23/34/43 and -ECx modules (8/4-2024) Version 3.54 MAC00-ECx_V3_54.zip
ZIP
MAC00-EIx_V3_44.zip
MIS17/23/34/43 and -EIx modules (4/4-2025) Version 3.44 MAC00-EIx_V3_44.zip
PDF
MAC00-EIx_V3_44.zip
MIS17/23/34/43 and -EIx modules (4/4-2025) Version 3.44 MAC00-EIx_V3_44.zip
ZIP
MAC00-ELx_V3_12.zip
MIS17/23/34/43 and -ELx modules (8/4-2024) Version 3.12 MAC00-ELx_V3_12.zip
PDF
MAC00-ELx_V3_12.zip
MIS17/23/34/43 and -ELx modules (8/4-2024) Version 3.12 MAC00-ELx_V3_12.zip
ZIP
MAC00-EMx_V3_28.zip
MIS17/23/34/43 and -EMx modules (4/4-2025) Version 3.28 MAC00-EMx_V3_28.zip
PDF
MAC00-EMx_V3_28.zip
MIS17/23/34/43 and -EMx modules (4/4-2025) Version 3.28 MAC00-EMx_V3_28.zip
ZIP
MAC00-EPx_V3_42.zip
MIS17/23/34/43 and -EPx modules (8/11-2023) Version 3.42 MAC00-EPx_V3_42.zip
PDF
MAC00-EPx_V3_42.zip
MIS17/23/34/43 and -EPx modules (8/11-2023) Version 3.42 MAC00-EPx_V3_42.zip
ZIP
MAC00-ESx_V3_16.zip
MIS17/23/34/43 and -ESx modules (8/4-2024) Version 3.16 MAC00-ESx_V3_16.zip
PDF
MAC00-ESx_V3_16.zip
MIS17/23/34/43 and -ESx modules (8/4-2024) Version 3.16 MAC00-ESx_V3_16.zip
ZIP
MAC00-FCx_v3_05.zip
Firmware for MAC00-FCx modules (x/x-20xx) EDS-file for MAC050-141 (-A) EDS-file for MAC400+ and Version 3.05 (ModBus supported) mac00-fc-SMAC mac00.fc-BMAC MAC00-FCx_v3_05.zip *
ZIP
MAC00-FDx_v3_00.zip
Firmware for MAC00-FDx modules (x/x-20xx) Version 3.0 (Modbus supported) MAC00-FDx_v3_00.zip
ZIP
MAC00-FP_v2_02HS.zip
Firmware for MAC00-FP modules (x/x-20xx) Version 3.04 (ModBus supported) Uses motor address Version 3.05 (Modbus supported) Uses dip-sw. at module Version 2.02HS MAC00-FP_v3_04.zip MAC00-FP_v3_05.zip MAC00-FP_v2_02HS.zip
ZIP
MAC00-FP_v3_04.zip
Firmware for MAC00-FP modules (x/x-20xx) Version 3.04 (ModBus supported) Uses motor address Version 3.05 (Modbus supported) Uses dip-sw. at module Version 2.02HS MAC00-FP_v3_04.zip MAC00-FP_v3_05.zip MAC00-FP_v2_02HS.zip
ZIP
MAC00-FP_v3_05.zip
Firmware for MAC00-FP modules (x/x-20xx) Version 3.04 (ModBus supported) Uses motor address Version 3.05 (Modbus supported) Uses dip-sw. at module Version 2.02HS MAC00-FP_v3_04.zip MAC00-FP_v3_05.zip MAC00-FP_v2_02HS.zip
ZIP
MAC00-FSx_v2_05.zip
Firmware for MAC00-FSx Version 2.05 (19/2-2019) Version 2.06 (10/4-2025) MAC00-FSx_v2_05.zip MAC00-FSx_v2_06.zip
ZIP
MAC00-FSx_v2_06.zip
Firmware for MAC00-FSx Version 2.05 (19/2-2019) Version 2.06 (10/4-2025) MAC00-FSx_v2_05.zip MAC00-FSx_v2_06.zip
ZIP
MAC00-Rx_v2_03.zip
Firmware for MAC00-Rx modules (x/x-2019) Version 2.03 MAC00-Rx_v2_03.zip
ZIP
MAC00-RxP_v3_01.zip
Firmware for MAC00-RxP modules (x/x-20xx) Version 3.01 MAC00-RxP_v3_01.zip

Config Files

ZIP
EtherNet/IP AOIs - Classic MAC with module
Add On Instructions for MAC-Motors
Download
ZIP
CANopen EDS file for MAC00-FCx
CANOpen EDS file for MAC00-FCxx modules This file covers MAC50-A to MAC141-A with firmware version 7.15 and later
Download
ZIP
DeviceNet EDS file for MAC00-FDx (Version 1.0)Download
ZIP
EtherNet/IP EDS file - Classic MAC with module
For MAC Integrated Servo Motors with Ethernet Module
Download
ZIP
EtherCAT ESI file - Classic MAC with module and MIS (version 26)
EtherCAT slave information file. JVL ECS V26. ( 20/5-2022 )
Download
ZIP
PROFIBUS GSD file (JVLI06BC)
Profibus GSD-file for MAC00-FPx modules (Version 1.2) JVLI06BC.zip
Download
ZIP
PROFINET GSDML file - Classic MAC and MIS / MIL (2024-04-23)
GSD file - 8 regs. PZD (2024-04-23 - From FW 3.40)
Download
ZIP
Powerlink MAC050-141, 5 regs - XDD fileDownload
ZIP
Powerlink MAC050-141, 8 regs - XDD fileDownload
ZIP
Powerlink MAC400+, 5 regs - XDD fileDownload
ZIP
Powerlink MAC400+, 8 regs - XDD fileDownload
ZIP
JVL Profinet Library V1.2 for TIA Portal
PROFINET IO example for TIA V14 or higher using funtion blocks. (JVL Profinet Library V1.2.zip)
Download

Report a problem or suggest a feature

Tell us what went wrong or what you are missing. The page you are on is sent with your message.

What kind of report?