A, B, Z - 5 V balanced
Pulse + direction, 5 V TTL
1024/2048/4096/8192 counts
1/4 of pulse input

Pulse/Direction to Encoder Signal Converter PA0095-1Obsolete

Converts a pulse and direction signal into an incremental encoder signal with index pulse. Useful when pulse/direction signals from a PLC stepper module have to be turned into an encoder signal, or when several axes must be synchronised from a pulse/direction source.

Key Features

  • ✓Converts pulse and direction to an incremental encoder signal with index pulse
  • ✓A, B and Z outputs are 5V balanced (A+, A-, B+, B-, Z+, Z-)
  • ✓Pulse and direction inputs at 5V TTL levels
  • ✓Selectable index pulse every 1024, 2048, 4096 or 8192 counts
  • ✓Index pulse (Z output) can be inverted at DIP switch 3
  • ✓Output signal direction can be inverted at DIP switch 4
  • ✓LEDs A and B show the output level directly; LED Z toggles on each index pulse
  • ✓Can be modified to other conversion functions on request
Contact Us
Note: Obsolete - product is discontinued and is no longer being produced.

[Obsolete. Product is discontinued and is no longer being produced]

In many automation applications it is very useful to be able to convert a pulse and direction signal into an incremental encoder signal. This is for instance required in the following cases:

  • When pulse direction signals from a PLC with step motor modules have to be converted to an encoder signal.
  • When several axes have to be synchronized and the input is pulse/direction.

The modules can easily be modified to other conversion functions. Please contact your local JVL representative or JVL A/S directly.

Description

A pulse and direction signal is converted to an incremental encoder signal with index pulse. A, B and Z out pulses are 5V balanced (A+, A-, B+, B-, Z+, Z-). The pulse and direction inputs are 5V TTL levels.

The index pulse is generated every time 1024, 2048, 4096 or 8192 (selectable) counts have been produced in the internal pulse/direction up/down counter. The output signal A or B is changed each time a pulse is applied to the pulse input. The frequency of the A or B signal will always be ¼ of the pulse input frequency.

As an extra feature the index pulse (Z output) can be inverted at dip-switch 3. Also the direction of the output signal can be inverted at dip-switch 4.

The LEDs "A" and "B" show directly what the level at the output is. The LED "Z" is not representing the actual output level but is toggled every time an index pulse is generated. The index pulse length is the distance between 2 counts - for example, if the input frequency is 1000 Hz, the index pulse will be 1/1000 = 1 ms.

Technical Specifications

FunctionPulse/direction to incremental encoder conversion
OutputsA+, A-, B+, B-, Z+, Z- - 5 V balanced
InputsPulse and direction, 5 V TTL
Index PulseEvery 1024, 2048, 4096 or 8192 counts (selectable)
Output FrequencyA or B is always 1/4 of the pulse input frequency
Index Pulse LengthOne count period - e.g. 1 ms at 1000 Hz input
DIP Switch 3Invert index (Z) output
DIP Switch 4Invert output direction
IndicatorsLEDs for A, B and Z