The JVL IO-Link is now built into the IO connectors of a JVL motor.

IO-Link is becoming increasingly popular as a low-cost alternative to Ethernet and other serial protocols.

JVL motors can now also connect to IO-Link with a built-in IO-Link for a fast and easy interface. It does not use an external gateway or CPU but communicates directly with the JVL main microprocessor for fast response time. Normally you would think IO-Link with a 230 kbit serial communication is slow compared to Ethernet, but with JVL's FastMAC 2-byte protocol a response time of less than 1 ms can be achieved.

IO-Link will be supported on all new JVL motors - MAC motor® integrated servo MACxx04/02 series and ServoStep™ integrated MISxx stepper motors.

JVL's IO-Link features

  • AOI and function block available for Rockwell and Siemens PLC
  • IODD files for plug-and-play simplified integration to PLC, supporting the different JVL modes of operation
  • Data storage for easy commissioning and replacement
  • Event handling for timestamped diagnostics
  • Any IO-Link master will be able to control the motor
  • All motion functions can be controlled through the IO-Link channel
  • All motor registers can be read or written
  • ModeFM - ultra compact processdata format with 2 bytes for extremely low IO-Link cycle time, less than 1 ms
  • One cable with both power and IO-Link for low-power applications
  • Minimize stock - available with both IO-Link and Ethernet based communication
  • Easy commissioning using IODD files and parametrization directly from the IO-Link master
  • Mode66 - 6 in / 6 out registers, similar to the well-known JVL Ethernet concept
  • Mode88 - 8 in / 8 out, 100% user-configurable register setup, similar to the well-known JVL Ethernet concept
  • Conformance tool tested and passed
  • IO-Link standard 1.1.4 supported
  • Specialized Gripper mode - simple control with high servo-controlled accuracy

Typical applications

  • Format adjustment - replacement of handwheel adjustment
  • Gripper with high precision and dynamics using the JVL ServoStepper™ control system
  • Pick-and-place operations - move between 2-8 pre-selected positions with pre-configured velocity, acceleration and torque setting
  • Air-cylinder replacement with precise acceleration and speed control
  • Setup axis, only requiring a minimal bandwidth and no hard timing or synchronization requirement
  • Topology Rockwell example: one IO-Link for each motor

Milestones for IO-Link Functionality

  • Q1 2025 - Data storage

For the technical reference, see the IO-Link protocol page.