Connect multiple JVL motors through low cost RS422 motors to an existing IOlink, CANopen, Wireless ethernet, Ethernet, DMX512 motor.
Topology One link , One motor for fast response on all motors
Features:
- Connect multiple JVL motors through low cost RS422 motors to an existing IOlink, CANopen , Wireless ethernet, Ethernet, DMX512 motor
- All motor can have MACtalk communication together with MODBUS or CAN communication
- Control multiple motors in daisy chain RS422 network
- Connect multiple JVL motors to an existing Ethernet based network ?
- Save between 10-15% in the investment costs when integrating JVL drives by using IOLink instead of an traditional Ethernet based control network.
- In 90% of the applications where JVL drives are used, the specific axis is used as a setup axis, only requiring a minimal of bandwith and no hard timing requirement
- For the Rockwell environment AOI’s are supported.
Features CAN:
- CAN motor have MACtalk +MODBUS + CAN communication at the same time
- Control motor point to point
- 1Mbit
Features IOLINK module WI1425x:
- By using IO-Link and the new JVL IO-Link gateway a JVL drive (servo or stepper) can be controlled directly from the PLC through an IO-Link Master.
- IOLINK demand gateway module with IOlink M12 5Pin in and 17pin out that connect to stepper or servomotor.
- Motor 1 should have a WI1425 module connected but additional motor can be low cost RS422 MIS*Q9* motors
- Connect multiple motor through a RS422 On same motor connect M12 8pin to motor 2 M12 17pin etc.
- IOLink compatible with Rockwell Armorblock 1732E-8IOLM12R, Siemens and others
- Max 1 Mbit RS422 for only MODBUS and IOLINK motor network.
- Even though the IO-Link based JVL control never was intended to be used in hard timing restrained application, reaction times an be very low.
- The JVL gateway is placed inside a rugged metal tube. 2 Leds indicates the current Link status.
- The metal gateway screws directly into one of the IO-connectors on the motor and an
- IO-Link cable is connected to the other end, that goes directly into the IO-Link master.
- The JVL Gateway is delivered with either 8, 12 or 17Pin connector depending on the
- type of JVL drive used.
- For the MIS motors an added bonus, up to 5 motors can be connected to one IO-Link channel by utilizing multidrop topology on an internal JVL bus, running between the motors.
- For the MAC servo motor range an MAC00-B4 module is required for each motor. Observe that these drives requires one IO-Link channel per. Drive.
- All normal motion functions can be controlled through the IO-Link channel.
- For the MIS Servo stepper series, the Gateway tube connects directly to the 17Pin connector.
Feature Wireless Ethernet:
- Wireless ethernet is build into motor so only antenna is outside. Use the motor internal switch to connect to multiple other Ethernet motor
- MODBUS motor ie 17 pin RS422 MODBUS input and 8 pin MODBUS output to multiple other RS422 motors.
- Use Master with 4-8 channels for point to point to each motor for fastest response. Use daizy chain connection for non timecritical application (The more motors the slower it gets).
- Max 460Mbit RS422 MODBUS for motor with Ethernet
- This Master usually connects directly to the PLC via the Ethernetbus.
| CANOpen | IOLINK | Ethernet Wired | Wireless Ethernet | DMX512 | J1939 | Master slave MODBUS | Slave follow MODBUS | |
| Hardware Physical layer | CAN RS485 | IOLink 24V seriel WI1425M12M5TM17T201 | Ethernet | Wifi+Profinet/EthernetIP ModbusTCP/UDP | RS485 or RS422 | CAN RS485 | RS422 duplex | RS422 duplex |
| JVL MACmotor module | MAC00-FC41 | MAC00-Ex41: WI1425M12M5TM17T201 MAC00-B41: WI1425M12M5TM12T201 MAC00-B4 : WI1425M12M5TM8T501 | - | MAC00-WI ( EthernetIP) MAC00-WP (Profinet) MAC00-WM ( MODBUS TCP/UDP) | MAC00-FS4 | n/a | MAC00-B4 MAC00-B41 MAC00-Ex4 | |
| JVL motor MIS/SMC66/85 | MIS/SMC*P6* | WI1425M12M5TM17T201+ MIS/SMC*Q5/Q9 | MIS/SMC* E2 Ethercat+MOSBUS E3: Ethernet/IP+MODBUS E4:Powerlink+RS422 E5: Modbus TCP+MODBUS E6: Profinet+SSI | MIS/SMC WI ( EthernetIP) WP(Profinet) WM ( MODBUS TCP/UDP) | MIS/SMC*Q5/Q9 | MIS/SMC*P6* | MIS/SMC*Q5/Q9 | MIS/SMC*Q5/Q9 |
| AIO support | PDO Max5 motors with multidrop | |||||||
| Max number of nodes. Address range | 255 | 255 | 65535 | 512 | ||||
| Syncronization | Yes | No | ||||||
| Cyclic Sync cycletimes | ||||||||
| Minimum cycle time | 1mS for 5 Reg | |||||||
| Drive profile | CiA402 | Planned Profidrive | No | |||||
| Daicychain | Yes 5pin M 5p Female | Yes | Yes Wireless ethernet in. Ethernet or MODBUS out | |||||
| Communications speed | 460 kbit | 9.6 to 921kbit | ||||||
| Reaction time | ||||||||
| Read & write IO+reg in motor | Yes | Yes | Yes | Yes | Yes | Yes | ||
| JVL AOI | Yes Rockwell | |||||||
| JVL Function Block | Yes Siemens Profinet | |||||||
| JVL Example | Yes Beckhoff | |||||||
| Motor suppported | MIS*Q5*/*Q9* | |||||||
| Protocol supported | ||||||||
| User organization | Link | Link | Link | Link | Link | Link |