Connect multiple JVL motors through low cost RS422 motors to an existing IOlink, CANopen, Wireless ethernet, Ethernet, DMX512 motor.

Topology One link , One motor for fast response on all motors

Features:

  • Connect multiple JVL motors through low cost RS422 motors to an existing IOlink, CANopen , Wireless ethernet, Ethernet, DMX512 motor
  • All motor can have MACtalk communication together with MODBUS or CAN communication
  • Control multiple motors in daisy chain RS422 network
  • Connect multiple JVL motors to an existing Ethernet based network ?
  • Save between 10-15% in the investment costs when integrating JVL drives by using IOLink instead of an traditional Ethernet based control network.
  • In 90% of the applications where JVL drives are used, the specific axis is used as a setup axis, only requiring a minimal of bandwith and no hard timing requirement
  • For the Rockwell environment AOI’s are supported.

Features CAN:

  • CAN motor have MACtalk +MODBUS + CAN communication at the same time
  • Control motor point to point
  • 1Mbit

Features IOLINK module WI1425x:

  • By using IO-Link and the new JVL IO-Link gateway a JVL drive (servo or stepper) can be controlled directly from the PLC through an IO-Link Master.
  • IOLINK demand gateway module with IOlink M12 5Pin in and 17pin out that connect to stepper or servomotor.
  • Motor 1 should have a WI1425 module connected but additional motor can be low cost RS422 MIS*Q9* motors
  • Connect multiple motor through a RS422 On same motor connect M12 8pin to motor 2 M12 17pin etc.
  • IOLink compatible with Rockwell Armorblock 1732E-8IOLM12R, Siemens and others
  • Max 1 Mbit RS422 for only MODBUS and IOLINK motor network.
  • Even though the IO-Link based JVL control never was intended to be used in hard timing restrained application, reaction times an be very low.
  • The JVL gateway is placed inside a rugged metal tube. 2 Leds indicates the current Link status.
  • The metal gateway screws directly into one of the IO-connectors on the motor and an
  • IO-Link cable is connected to the other end, that goes directly into the IO-Link master.
  • The JVL Gateway is delivered with either 8, 12 or 17Pin connector depending on the
  • type of JVL drive used.
  • For the MIS motors an added bonus, up to 5 motors can be connected to one IO-Link channel by utilizing multidrop topology on an internal JVL bus, running between the motors.
  • For the MAC servo motor range an MAC00-B4 module is required for each motor. Observe that these drives requires one IO-Link channel per. Drive.
  • All normal motion functions can be controlled through the IO-Link channel.
  • For the MIS Servo stepper series, the Gateway tube connects directly to the 17Pin connector.

Feature Wireless Ethernet:

  • Wireless ethernet is build into motor so only antenna is outside. Use the motor internal switch to connect to multiple other Ethernet motor
  • MODBUS motor ie 17 pin RS422 MODBUS input and 8 pin MODBUS output to multiple other RS422 motors.
  • Use Master with 4-8 channels for point to point to each motor for fastest response. Use daizy chain connection for non timecritical application (The more motors the slower it gets).
  • Max 460Mbit RS422 MODBUS for motor with Ethernet
  • This Master usually connects directly to the PLC via the Ethernetbus.
CANOpenIOLINKEthernet WiredWireless EthernetDMX512J1939Master slave MODBUSSlave follow MODBUS
Hardware Physical layerCAN RS485IOLink 24V seriel WI1425M12M5TM17T201EthernetWifi+Profinet/EthernetIP ModbusTCP/UDPRS485 or RS422CAN RS485RS422 duplexRS422 duplex
JVL MACmotor moduleMAC00-FC41MAC00-Ex41: WI1425M12M5TM17T201 MAC00-B41: WI1425M12M5TM12T201 MAC00-B4 : WI1425M12M5TM8T501-MAC00-WI ( EthernetIP) MAC00-WP (Profinet) MAC00-WM ( MODBUS TCP/UDP)MAC00-FS4n/aMAC00-B4 MAC00-B41 MAC00-Ex4
JVL motor MIS/SMC66/85MIS/SMC*P6*WI1425M12M5TM17T201+ MIS/SMC*Q5/Q9MIS/SMC* E2 Ethercat+MOSBUS E3: Ethernet/IP+MODBUS E4:Powerlink+RS422 E5: Modbus TCP+MODBUS E6: Profinet+SSIMIS/SMC WI ( EthernetIP) WP(Profinet) WM ( MODBUS TCP/UDP)MIS/SMC*Q5/Q9MIS/SMC*P6*MIS/SMC*Q5/Q9MIS/SMC*Q5/Q9
AIO supportPDO Max5 motors with multidrop
Max number of nodes. Address range25525565535512
SyncronizationYesNo
Cyclic Sync cycletimes
Minimum cycle time1mS for 5 Reg
Drive profileCiA402Planned ProfidriveNo
DaicychainYes 5pin M 5p FemaleYesYes Wireless ethernet in. Ethernet or MODBUS out
Communications speed460 kbit9.6 to 921kbit
Reaction time
Read & write IO+reg in motorYesYesYesYesYesYes
JVL AOIYes Rockwell
JVL Function BlockYes Siemens Profinet
JVL ExampleYes Beckhoff
Motor suppportedMIS*Q5*/*Q9*
Protocol supported
User organizationLinkLinkLinkLinkLinkLink