Industrial Ethernet for SMC66/85 and MIS17/23xQ/R/S/T & MIS34x

Industrial Ethernet is the name given to the use of the Ethernet network protocol in an industrial environment, for automation and process control.

A number of techniques are used to adapt the Ethernet protocol for the needs of industrial processes, which must provide real time behavior.

By using non-proprietary protocols, automation systems from different manufacturers can be interconnected throughout a process plant.

Industrial Ethernet takes advantage of the relatively larger marketplace for computer interconnections to reduce cost and improve performance of communications between industrial controllers.

Industrial Ethernet (IE) components used in plant process areas must be designed to work in harsh environments of temperature extremes, humidity, and vibration that exceed the ranges for IT equipment intended for installation in controlled environments.

Read more in these articles.

Industrial Ethernet preferred Motion Controller Specialist Partners.

Read more about Sercos III

Find Industrial Ethernet Specification files and PLC demo programs here

Download JVL Addon Instructions for MIS motors here.

Link to conformance test

EtherCATEtherNet/IPPROFINET IOSERCOSModbus TCP Modbus UDPEtherNet Powerlink
HardwareOption Built-inOption Built-inOption Built-inOption Built-inOption Built-inOption Built-in
AvailableYesYesYesYesYesYes
Application ProtocolCANopen (DS301 + DSP402)CIPProfinet IOSERCOSIII ver. 1.1.2ModbusCANopen
CompanyBeckhoffRockwell AutomationSiemensBosch RexrothB&R
MacTalk over RS485:YesYesYesYesYesYes
IIoT, IoT, Industrie 4.0:*2)YesYesYesYesYesYes
MacTalk over Ethernet: Scope: ePLC transfer: Load Default: Firmware Update:Yes*3) Planned Yes*3) Yes*3) PlannedYes Planned Yes Yes YesYes Planned Yes Yes YesYes*4) Planned Yes*4) Yes*4) Yes*4)Yes Planned Yes Yes YesNo plan No plan No plan No Plan No Plan
Transport ProtocolEtherCAT EtherCAT/UDPTCP/IP, UDP/IPTCP/IP, UDP/IP, Profinet RTTCP/IP, UDP/IPPowerlink V2
SyncronizationDC, 32bitPlannedPlannedYes-Planned
Drive profileCiA402PlannedPlannedYes-Planned
Sync. cycletimes1, 2, 3 or 4 ms--1, 2, 3, 4, 6 or 8 ms--
Sync. jitter+/-1us--+/-1us--
Network Minimum cycle time<50 µs2 ms1 ms250 µs~2 ms<200 µs
Module Minimum cycle time360µs at 1/1 500µs at 5/5 605µs at 8/8 *1)1 ms1 ms at 5/5 1.2 ms at 8/8500 µsNot Cyclic: 1 reg. 1ms 10 reg. 4ms360µs at 1/1 500µs at 5/5 605µs at 8/8 *1)
Address Range65535655356553551165535256
Max. BaudrateEthernet 100Mbit/sEthernet 100Mbit/sEthernet 100Mbit/sEthernet 100Mbit/sEthernet 100Mbit/sEthernet 100Mbit/s
Forwarding delay<1 µs10-130 µs3.25 µs<1 µs10-130 µs0.5 µs
NetworkLine, Ring, Star, TreeSwitches, routers, wirelessSwitches, routers, wirelessLine, RingSwitches, routers, wirelessLine, Star, Tree
StandardsIEC 61158, IEC/PAS 62407 IEC 61784-3 ISO 15745-4IEC 61158/ IEC 61784/ ODVA Ethernet/IP standardIEC 61158/ IEC 61784IEC 61491 merged into IEC 61158IEC 61158/ IEC 61784IEC 61158, EPSG (Ethernet Powerlink Standarization Group)
Further sup****ported protocolsSDO, CoEDHCP, ACD, DLRRTC class 1-3, RTA , DCP, CL-RCP,LLDP, SNMP, MRP client---DHCP---
Compatible with WIFI moduleNoFW 3.40FW 3.40NoFW 3.24No
User org.ETGODVAProfibus int.Sercos North America, Sercos InternationalModbus Org.EPSG

*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8.

*2) IIoT: Industrial Internet of things, IoT: Internet of things.

*3) Requirements: EtherCAT Master.

*4) Connect to Sercos master when using ring topology otherwise connect to last motor in line.