Industrial Ethernet is the name given to the use of the Ethernet network protocol in an industrial environment, for automation and process control.
A number of techniques are used to adapt the Ethernet protocol for the needs of industrial processes, which must provide real time behavior.
By using non-proprietary protocols, automation systems from different manufacturers can be interconnected throughout a process plant.
Industrial Ethernet takes advantage of the relatively larger marketplace for computer interconnections to reduce cost and improve performance of communications between industrial controllers.
Industrial Ethernet (IE) components used in plant process areas must be designed to work in harsh environments of temperature extremes, humidity, and vibration that exceed the ranges for IT equipment intended for installation in controlled environments.
Industrial Ethernet preferred Motion Controller Specialist Partners.
Find Industrial Ethernet Specification files and PLC demo programs here
Download JVL Addon Instructions for MIS motors here.
| EtherCAT | EtherNet/IP | PROFINET IO | SERCOS | Modbus TCP Modbus UDP | EtherNet Powerlink | |
![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |
| Hardware | Option Built-in | Option Built-in | Option Built-in | Option Built-in | Option Built-in | Option Built-in |
| Available | Yes | Yes | Yes | Yes | Yes | Yes |
| Application Protocol | CANopen (DS301 + DSP402) | CIP | Profinet IO | SERCOSIII ver. 1.1.2 | Modbus | CANopen |
| Company | Beckhoff | Rockwell Automation | Siemens | Bosch Rexroth | B&R | |
| MacTalk over RS485: | Yes | Yes | Yes | Yes | Yes | Yes |
| IIoT, IoT, Industrie 4.0:*2) | Yes | Yes | Yes | Yes | Yes | Yes |
| MacTalk over Ethernet: Scope: ePLC transfer: Load Default: Firmware Update: | Yes*3) Planned Yes*3) Yes*3) Planned | Yes Planned Yes Yes Yes | Yes Planned Yes Yes Yes | Yes*4) Planned Yes*4) Yes*4) Yes*4) | Yes Planned Yes Yes Yes | No plan No plan No plan No Plan No Plan |
| Transport Protocol | EtherCAT EtherCAT/UDP | TCP/IP, UDP/IP | TCP/IP, UDP/IP, Profinet RT | TCP/IP, UDP/IP | Powerlink V2 | |
| Syncronization | DC, 32bit | Planned | Planned | Yes | - | Planned |
| Drive profile | CiA402 | Planned | Planned | Yes | - | Planned |
| Sync. cycletimes | 1, 2, 3 or 4 ms | - | - | 1, 2, 3, 4, 6 or 8 ms | - | - |
| Sync. jitter | +/-1us | - | - | +/-1us | - | - |
| Network Minimum cycle time | <50 µs | 2 ms | 1 ms | 250 µs | ~2 ms | <200 µs |
| Module Minimum cycle time | 360µs at 1/1 500µs at 5/5 605µs at 8/8 *1) | 1 ms | 1 ms at 5/5 1.2 ms at 8/8 | 500 µs | Not Cyclic: 1 reg. 1ms 10 reg. 4ms | 360µs at 1/1 500µs at 5/5 605µs at 8/8 *1) |
| Address Range | 65535 | 65535 | 65535 | 511 | 65535 | 256 |
| Max. Baudrate | Ethernet 100Mbit/s | Ethernet 100Mbit/s | Ethernet 100Mbit/s | Ethernet 100Mbit/s | Ethernet 100Mbit/s | Ethernet 100Mbit/s |
| Forwarding delay | <1 µs | 10-130 µs | 3.25 µs | <1 µs | 10-130 µs | 0.5 µs |
| Network | Line, Ring, Star, Tree | Switches, routers, wireless | Switches, routers, wireless | Line, Ring | Switches, routers, wireless | Line, Star, Tree |
| Standards | IEC 61158, IEC/PAS 62407 IEC 61784-3 ISO 15745-4 | IEC 61158/ IEC 61784/ ODVA Ethernet/IP standard | IEC 61158/ IEC 61784 | IEC 61491 merged into IEC 61158 | IEC 61158/ IEC 61784 | IEC 61158, EPSG (Ethernet Powerlink Standarization Group) |
| Further sup****ported protocols | SDO, CoE | DHCP, ACD, DLR | RTC class 1-3, RTA , DCP, CL-RCP,LLDP, SNMP, MRP client | --- | DHCP | --- |
| Compatible with WIFI module | No | FW 3.40 | FW 3.40 | No | FW 3.24 | No |
| User org. | ETG | ODVA | Profibus int. | Sercos North America, Sercos International | Modbus Org. | EPSG |
*1) Reading 1 register and writing to 1 register or 5 and 5 or 8 and 8.
*2) IIoT: Industrial Internet of things, IoT: Internet of things.
*3) Requirements: EtherCAT Master.
*4) Connect to Sercos master when using ring topology otherwise connect to last motor in line.